Permit: T03BU02451

Parcel: 122153120

Inspection Status: Approved

Inspection History: GRADING - FINAL

Date Description Inspector Results Comments
06/10/2005 GRADING - FINAL Approved
03/11/2005 GRADING - FINAL Denied 1. PROVIDE 3:1 SLOPES ON RETENTION/DETENTION BASIN WEST OF BUILDING. SEE KEYNOTE 4.
2. CONSTRUCT RIP RAP SPILLWAY PER PLAN DETAIL 15, SHEET C3.4. KEYNOTE 31
3. PROVIDE CONCRETE SPLASH BLOCKS AT DOWNSPOUTS AS INDICATED ON THE PLAN. KEYNOTE 27
4. PROVIDE (2) STOP BARS AT THE NORTH ENTRANCE DRIVES. SEE KEYNOTE 25 & 50
5. PROVIDE NO PARKING SIGNS AT THE SOUTHEAST CORNER OF SITE.
6. GRADE THE EARTHEN SWALE TO DAYLIGHT A 1% MIN. NEAR SOUTH PERIMETER. KEYNOTE 15
7. PROVIDE ENGINEERS REPORT FOR R/D BASIN. SEE NOTE 2 PAGE C-3.4
8. PROVIDE SOLID LID FOR SERVICE MANHOLE.