Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T03BU02419
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/24/2003 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection 0000* | |
11/06/2003 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection 0000* FOOTINGS REQUIRED UNDER POSTS 16" X 16" X 12" DEEP REQUIRED UNDER ALL POSTS. FOOTING MUST BE POSITIVELY ATTACHED TO POST BASE. 2) H2.5 CLIPS REQUIRED BEAM TO RAFTER. 3) A35 OR H2.5 CLIPS REQUIRED RAFTER TO EXSISTING WALL. |