Inspection History Details
Permit: T03BU02138
Inspection Status: Approved
Inspection History: STORMWATER INSTALL OF CONTROLS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/17/2004 | STORMWATER INSTALL OF CONTROLS | Approved | ||
| 08/10/2004 | STORMWATER INSTALL OF CONTROLS | Correction Required | 1. PROVIDE STABILIZED CONSTRUCTION ENTRANCE ON WEST SIDE OF SITE OR REVISE PLAN TO SHOW RELOCATION. 2. POST NOTICE OF INTENT AND LOCATION OF SWPPP AT THE MAIN ENTRANCE. 3. PROVIDE STORMWATER CONTROLS DOWN GRADIENT FROM THE STOCKPILE AND THE SEWER EXCAVATION. |
|
| 07/29/2004 | STORMWATER INSTALL OF CONTROLS | Correction Required | NO SUPERINTENDENT OF SITE. INSPECTION RESCHEDULED |
|
| 07/01/2004 | STORMWATER INSTALL OF CONTROLS | Correction Required | 1. PROVIDE STABILIZED CONSTRUCTION ENTRANCE ON WEST SIDE OF SITE OR REVISE PLAN TO SHOW RELOCATION. 2. POST NOTICE OF INTENT AND LOCATION OF SWPPP AT THE MAIN ENTRANCE.. 3. PROVIDE A COMPLETE COPY OF THE SWPPP AT THE SITE.. 4. RELOCATED WEST PERIMETER SILT FENCING UP GRADIENT FROM UNDISTURBED NATURAL AREA. BURY SILT FENCING BOTTOM 6" -8" DEEP. |