Inspection Status: Approved
Inspection History: POOL/SPA PRE-GUNITE
| Date |
Description |
Inspector |
Results |
Comments |
| 10/15/2003 |
POOL/SPA PRE-GUNITE |
|
Approved |
IVRS - Inspection 0000* |
| 10/13/2003 |
POOL/SPA PRE-GUNITE |
|
Denied |
IVRS - Inspection 0999*/ 1) 3" CLEARANCE AT SPA STEEL 2) SHADE ALL PLASTIC 3) REMOVE GAS LINE OR 18" BURIAL 4) BOND AND CONDUIT ONLY |
| 10/09/2003 |
POOL/SPA PRE-GUNITE |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) CANCELLED ON SITE |
| 10/07/2003 |
POOL/SPA PRE-GUNITE |
|
Denied |
IVRS - Inspection 0999*/ 1) WATER PRESSURE TOO LOW 2) CANNOT READ GAS LINE PRESSURE GAUGE 3) UNCOVER GAS LINE AT HOUSE REQUIRES 30" SWEEP AT BOTH ENDS 4) 18" MINIMUM BURIAL ON GAS LINE, (6) CONDUIT, WATER LINES (12") 5) SHADE, REMOVE ROCKS AND PROTECT ALL GAS AND WATER LINES 6) COPPER CANNOT TOUCH INCOMPATIBLE MATERIAL 7) SPA SET BACK DOES NOT MATH PLAN 8) 3/4" CLEARANCE AT PIPE TO STEEL 9) 3" CLEARANCE AT STEEL TO FORMS 10) OPTION AT SPA DOES NOT INDICATE SAND BAGS |