Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03BU01324
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/14/2003 | FRAMING | Approved | ||
06/09/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) FRAMING IS ALMOST PER PLAN BUT I HAVE A QUESTION ABOUT DETAIL 1. TYPICALLY CITY OF TUCSON DOES NOT ALLOW LEDGER TO BE BOLTED ONTO WALL THROUGH FOAM/STUCCO. IN ADDITION THE PLAN CALLS FOR 3 EACH 5" LONG LAG BOLTS 16" ON CENTER BUT DOES NOT SPECIFY DIAMETER. YOU HAVE INSTALLED 2 EACH 16" ON CENTER |