Permit: T03BU01255

Parcel: 140441940


Addresses:

5803 E FARMSTEAD DR


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T03BU01255

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
08/07/2003 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*
08/05/2003 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999* 1)3" CLEARANCE REQUIRED FROM REBAR TO EARTH IN FOOTINGS. 2) 2" CLEARANCE REQUIRED FROM REBAR TO EDGE OF FORM.EARTH AROUND FORMED FOOTINGS WILL HAVE TO BE COMPACTED TO 95% AFTER FORMS ARE STRIPPED. 3) POST AN ADDRESS.