Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/21/2003 | ROOF NAILING | Approved | IVRS - Inspection 0000* | |
| 07/11/2003 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) ART MATHIESON DID THIS INSPECTION PER CUSTOMERS REQUEST. 2-2 X 4 AT COLUMNS. BOLTS AT LEDGER AT BLOCK WALLS. JOIST HANGERS AT FACIA | |
| 07/08/2003 | ROOF NAILING | Denied | IVRS - Inspection 0999* 1) PORCH BEAMS MUST BE SUPPORTED BY 4 X 6 POSTS PER PLAN. 2) ROOF SUPPORTING BEAM MUST BE 4 X 12 - 4 X 10 INSTALLED. 3) RAFTER MUST BE SUPPORTED BY A 2 X 8 LEDGER CONNECTED TO EXSISTING HOUSE WALL. NOT CONNECTED TO 2X FACIA FROM PRE EXSISTING ROOF. BUILD TO PLAN OR HAVE REVISED TO AS BUILT AND APPROVED BY COT. 4) PORCH POSTS MISSING AC-6 AND ABA46 BASES & CAPS. CANNOT APPROVE ROOF NAILING UNTIL PROJECT IS BUILT PER PLAN |