Permit: T03BU00789

Parcel: 141153420

Inspection Status: Not ready for Inspection

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
05/21/2003 ROOF NAILING Not ready for Inspection IVRS - Inspection 0000*
05/21/2003 ROOF NAILING Approved IVRS - Inspection 0000*
05/20/2003 ROOF NAILING Denied IVRS - Inspection 0999*
NO ANSWER @ THIS #.
1.) ROOF SHEATHING TO BE NAILED (NOT SCREWED @ 6" O.C. @ EDGES & 12" O.C. @ FIELD.
03/31/2003 ROOF NAILING Denied IVRS - Inspection 0999* 1.) USE CORRECT SIZE OF POST BASE FOR 4 X 6 POST.
2.) LEDGER MUST BE POSITIVELY ATTACHED TO HOUSE FRAME, YOU MAY NOT BOLT THROUGH STUCCO & FOAM.
3.) YOU NEED TO KEEP HOLES DRILLED FOR LAG BOLTS 1 1/2" - 2" FROM BOTTOM OR TOP OF LEDGER.