Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03BU00727


Addresses:

3333 N WALNUT AV

Inspection Status: Approved

Inspection History: GRADING - FINAL

Date Description Inspector Results Comments
02/18/2009 GRADING - FINAL Approved TALKED TO BRYAN/RICK ENGINEERING ABOUT THE REVISED AS-BUILTS, HE WILL HAVE THEM DELIVERED TO LAITH ALSHAMI THIS WEEK.
07/01/2008 GRADING - FINAL Approved
03/21/2008 GRADING - FINAL Denied PREVIOUS INSPECTION COMMENTS HAVE NOT BEEN ADDRESSED. I SPOKE TO WOCKY 405-3846, SHE IS WORKING FOR KB HOMES TO CLOSE OUT OLD PROJECTS. SHE STATED THAT SHE WOULD CONTACT JACK FOSTER OF RICK ENGINEERING TO HAVE PLAN REVISED AND APPROVED BY C.O.T ENGINEERING. THE REVISED PLAN WAS NOT AVAILABLE FOR THIS INSPECTION ALL COMMENTS REMAIN IN PLACE FOR EXISTING APPROVED PLAN.

PERMITEE QUALIFYS FOR INSPECTION RE-FEE DUE TO OUTSTANDING ITEMS ON PUNCHLIST.
05/23/2007 GRADING - FINAL Denied I MET WITH JACK FOSTER AND KB HOMES REGARDING PREVIOUS PUNCH LIST FOR FINAL GRADING. TWO ADDITIONAL ITEMS WERE ADDED TO CLARIFY ITEMS LISTED ON PREVIOUS PUNCH LIST (SEE ITEMS 12 AND 13).

1. PROVIDE A LETTER OF CERTIFICATION FROM AN ARIZONA REGISTERED PROFESSIONAL ENGINEER THAT CERTIFYS THAT THE PROJECT WAS CONSTRUCTED IN CONFORMANCE WITH THE APPROVED GRADING PLANS AND THAT THE DRAINAGE WILL FUNCTION AS DESIGNED.
2. COMPLETE ALL PERIMETER GRADING AND DRAINAGE AS SHOWN ON THE APPROVED GRADING PLAN.
3. PROVIDE POSITIVE DRAINAGE AT THE REAR OF LOTS 1-9 ON THE NORTH PERIMETER. GRADE TO THE FLOWLINE ELEVATIONS SHOWN ON THE APPROVED GRADING PLAN. SEE SLOPE DETAIL J, PAGE 3. AND GENERAL NOTE #12, PAGE.
4. PROVIDE WALL OPENINGS FOR LOT DRAINAGE OF LOTS 6-9. SEE DETAIL H, PAGE 3.
5. CLEAN OUT THE PORTION OF WALNUT WASH WITHIN THE GRADING LIMITS AT THE NORTHWEST CORNER OF SITE. PROVIDE A SMOOTH SURFACE AND UNIFORM CROSS SECTION ON THE SLOPES.
6. PROVIDE POSITIVE DRAINAGE AT THE WEST PERIMETER OF THE SITE ADJACENT TO LOTS 23,24,37 AND 38. GRADE TO THE FLOWLINE ELEVATIONS SHOWN ON THE APPROVED GRADING PLAN. SEE SLOPE DETAIL F, PAGE 3. AND GENERAL NOTE #12, PAGE.
7. REMOVE SILT FENCE AT WEST PERIMETER AND METAL T-POSTS ON EAST PERIMETER
8. CONSTRUCT PEDESTRIAN TRAIL SECTION AT SOUTHEAST CORNER OF SITE TO GRADING PLAN DETAIL C,PAGE 3.
9. PROVIDE A C.O.T.APPROVED DRAWING THAT SHOWS AREA DRAINS AND UNDERGROUND DRAINAGE PIPES SOUTH OF LOT 38.
10. RE-INSTALL FENCE AND POST AT WATER LINE COMPOUND AT THE SOUTHEAST CORNER OF THIS SITE.
11. CONSTRUCT SITE TO GRADING PLAN SPECIFICATIONS OR SUBMIT A REVISED GRADING PLAN TO THE CITY OF TUCSON, DEVELOPMENT SERVICES ENGINEERING AND ZONINGDIVISIONS, FOR REVIEW AND APPROVAL.
12. UN-COVER MONITORING WELL AT NORTHWEST CORNER OF SITE.
13. ADDRESS OFF-SITE DRAINAGE RUN-ON TO THE SOUHEAST CORNER OF THIS SITE.
02/15/2007 GRADING - FINAL Denied 1. PROVIDE A LETTER OF CERTIFICATION FROM AN ARIZONA REGISTERED PROFESSIONAL ENGINEER THAT CERTIFYS THAT THE PROJECT WAS CONSTRUCTED IN CONFORMANCE WITH THE APPROVED GRADING PLANS AND THAT THE DRAINAGE WILL FUNCTION AS DESIGNED.
2. COMPLETE ALL PERIMETER GRADING AND DRAINAGE AS SHOWN ON THE APPROVED GRADING PLAN.
3. PROVIDE POSITIVE DRAINAGE AT THE REAR OF LOTS 1-9 ON THE NORTH PERIMETER. GRADE TO THE FLOWLINE ELEVATIONS SHOWN ON THE APPROVED GRADING PLAN. SEE SLOPE DETAIL J, PAGE 3. AND GENERAL NOTE #12, PAGE.
4. PROVIDE WALL OPENINGS FOR LOT DRAINAGE OF LOTS 6-9. SEE DETAIL H, PAGE 3.
5. CLEAN OUT THE PORTION OF WALNUT WASH WITHIN THE GRADING LIMITS AT THE NORTHWEST CORNER OF SITE. PROVIDE A SMOOTH SURFACE AND UNIFORM CROSS SECTION ON THE SLOPES.
6. PROVIDE POSITIVE DRAINAGE AT THE WEST PERIMETER OF THE SITE ADJACENT TO LOTS 23,24,37 AND 38. GRADE TO THE FLOWLINE ELEVATIONS SHOWN ON THE APPROVED GRADING PLAN. SEE SLOPE DETAIL F, PAGE 3. AND GENERAL NOTE #12, PAGE.
7. REMOVE SILT FENCE AT WEST PERIMETER AND METAL T-POSTS ON EAST PERIMETER
8. CONSTRUCT PEDESTRIAN TRAIL SECTION AT SOUTHEAST CORNER OF SITE TO GRADING PLAN DETAIL C,PAGE 3.
9. PROVIDE A C.O.T.APPROVED DRAWING THAT SHOWS AREA DRAINS AND UNDERGROUND DRAINAGE PIPES SOUTH OF LOT 38.
10. RE-INSTALL FENCE AND POST AT WATER LINE COMPOUND AT THE SOUTHEAST CORNER OF THIS SITE.
11. CONSTRUCT SITE TO GRADING PLAN SPECIFICATIONS OR SUBMIT A REVISED GRADING PLAN TO THE CITY OF TUCSON, DEVELOPMENT SERVICES ENGINEERING AND ZONING DIVISIONS, FOR REVIEW AND APPROVAL.