Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
| Date |
Description |
Inspector |
Results |
Comments |
| 05/21/2003 |
POOL/SPA FINAL/BARRIER |
|
Approved |
IVRS - Inspection 0000* |
| 05/16/2003 |
POOL/SPA FINAL/BARRIER |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) RAISED POOL WALL AT WATER EDGE, REQUIRES HAND HOLDS AT 4'-0" ON CENTER 2) WEST NICHE FIXTURE REQUIRES A LISTED J-BOX WITH CORD RESTRAINT 3) POTTING COMPOUND ON LIGHT BOND CONNECTION AND SEAL CONDUIT WITH COMPOUND BOTH ENDS 4) METAL FENCE TO BE BONDED IF CLOSER THAN 5'-0" TO WATER EDGE 5) SERVICE OUTLET AT FILTER AND J-BOX, OUTLET TO BE GFCI PROTECTED 17 MAY BE ALREADY I'M NOT SURE, GFC BREAKER IN SUB-PANEL WAS DOUBLE FED, DON'T DO THAT, (POOL LIGHT AND OUTLE)? 6) YOU NEED TO HAVE LISTING FOR J-BOX APPROVAL OR INSTALL ONE THAT'S APPROVED 7) LEAVE POWER OFF AND OPEN ALL BOXES FOR INSPECTION (WATER DEPTH 3'-6" OR MORE WATER LEVEL ( HANDHOLD AT WATER LEVEL |