Inspection Status: Approved
Inspection History: STUCCO MESH
| Date |
Description |
Inspector |
Results |
Comments |
| 04/03/2003 |
STUCCO MESH |
|
Approved |
IVRS - Inspection 0000*/ 1) TIE INSIDE CORNERS WITH LATH |
| 03/27/2003 |
STUCCO MESH |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NO STUCCO DETAILS ON PLAN 2) NEED EXPANSION JOINT METAL AT ONE TO NEW STUCCO 3) FINISH NAILING WIRE 4) UNDERNEATH CEILING, NEED STUCCO STOP AT 2 X 6 FLOOR JOIST 5) SEALING FLOOR, WALL AND STUCCO STOP AT BOTTOM OF INSIDE PARAPET, PROBLEM 6) HORIZONTAL HOLE CUT FOR LEDGER NEEDS WEATHER RESISTING MATERIAL UNDER FLASHING 7) SUGGESTION GO WEST 1/2 BLOCK 2 STORY UNDER CONSTRUCTION SEE HOW THEY DO IT. IT'S A PROVEN METHOD |
| 03/25/2003 |
STUCCO MESH |
|
Not ready for Inspection |
IVRS - Inspection 0000* |