Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03BU00416

Parcel: 141302380

Inspection Status: Approved

Inspection History: STUCCO MESH

Permit Number - T03BU00416

Inspection Description - STUCCO MESH

Inspection Status - Approved

Date Description Inspector Results Comments
04/03/2003 STUCCO MESH Approved IVRS - Inspection 0000*/ 1) TIE INSIDE CORNERS WITH LATH
03/27/2003 STUCCO MESH Not ready for Inspection IVRS - Inspection 0000*/ 1) NO STUCCO DETAILS ON PLAN 2) NEED EXPANSION JOINT METAL AT ONE TO NEW STUCCO 3) FINISH NAILING WIRE 4) UNDERNEATH CEILING, NEED STUCCO STOP AT 2 X 6 FLOOR JOIST 5) SEALING FLOOR, WALL AND STUCCO STOP AT BOTTOM OF INSIDE PARAPET, PROBLEM 6) HORIZONTAL HOLE CUT FOR LEDGER NEEDS WEATHER RESISTING MATERIAL UNDER FLASHING 7) SUGGESTION GO WEST 1/2 BLOCK 2 STORY UNDER CONSTRUCTION SEE HOW THEY DO IT. IT'S A PROVEN METHOD
03/25/2003 STUCCO MESH Not ready for Inspection IVRS - Inspection 0000*