Inspection Status: Approved
Inspection History: POOL/SPA HEATER
| Date |
Description |
Inspector |
Results |
Comments |
| 03/20/2003 |
POOL/SPA HEATER |
|
Approved |
IVRS - Inspection 0000* |
| 03/19/2003 |
POOL/SPA HEATER |
|
Denied |
IVRS - Inspection 0999*/ 1) YOU HAVE VALVES ON BOTH INLET AND OUTLET SIDE OF HEATER BETWEEN POOL. (CLOSED SYSTEM) PROVIDE AN APPROVED TEMPERATURE PRESSURE RELIEF VALVE OR PROOF THAT ONE IS NOT NEEDED (HEATER INSTALLATION MANUAL) 2) BARRIER IS OK BUT CANNOT APPROVE UNTIL HEATER IS APPROVED 3) YOU MAY PLASTER POOL |
| 02/25/2003 |
POOL/SPA HEATER |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS TO CHECK FOR A PRESSURE RELIEF VALVE INSTALLATION FOR THIS HEATER 2) GAS CARD WILL BE ISSUED AT FINAL |