Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA ELECTRIC
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/2003 | POOL/SPA ELECTRIC | Approved | IVRS - Inspection 0000*/ 1) OK POOL ELECTRIC | |
| 07/15/2003 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000*/ 1) POTTING COMPOUND IS NEEDED AT FORMING SHELL 600-20 (10)(2) | |
| 06/16/2003 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000*/ 1) OK BONDING FOR HANDRAILS AND HANDICAP RAIL 2) PLEASE RECALL TO CHECK INSTALLATION OF LIGHTS BEFORE WATER | |
| 05/06/2003 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000*OK SHELL BONDING OK TO GUNITE. 1.) PLEASE RECALL FOR COOL DECK BONDING. |
|
| 05/05/2003 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection 0999* 1.) NO MORE THAN 360 ALLOWED IN PVC CONDUIT RUNS. 2.) IT IS NOT THE STANDARD TO RUN PVC IN THE GUNITE SHELL ALL THOUGH THE CODE DOES NOT SPECIFY THSI 680-10. 3.) PLEASE RECALL TO VERIFY CONDUIT RUN BE FOR GUNITE. |