Permit: T03BU00213

Parcel: 141195060

Inspection Status: Approved

Inspection History: POOL/SPA PRE-GUNITE

Date Description Inspector Results Comments
03/05/2003 POOL/SPA PRE-GUNITE Approved IVRS - Inspection 0000*
02/18/2003 POOL/SPA PRE-GUNITE Denied IVRS - Inspection 0999*/ 1) GAS LINE CANNOT CROSS ONTO ADJOINING PROPERTY 2) PLAN CALLS FOR POOL 5' FROM HOUSE ONLY 4' REVISE PLAN 3) POOL HAS SURCHARGE FROM HOUSE-NOT ALLOWED PER B/S2 PROVIDE ENGINEERING AND CITY OF TUCSON APPROVED REPAIR 4) 8/S1 AND 9/S1 NOT COMPLIED WITH
02/13/2003 POOL/SPA PRE-GUNITE Denied IVRS - Inspection 0999*/ 1) UNABLE TO CHECK PLUMBING FOR LEAKS TO WET RAINING 2) NO BONDING WITHIN 5' OF HOUSE/STUCTURES 3) NO ELECTRIC IN TRENCHES