Inspection Status: Correction Required
Inspection History: INITIAL CODE VIOLATION
| Date |
Description |
Inspector |
Results |
Comments |
| 12/20/2002 |
INITIAL CODE VIOLATION |
|
Correction Required |
IMPROPER DRAIN TO WASHER. ELECT. DROP TO LOW AT 7FT. TO SIDE OF UNIT. ELECT. WIRE NO CONDUIT TO WASHER AND DRYER. IMPROPER INSTALLATION OF WALL HEATER. WALL NOT FIRE RATED. NO SHEETROCK BEHIND UNIT. JUST PAINT- VERY THIN WALL. BEDROOM/BIRDROOM NO CONDUIT TO OVERHEAD LIGHT. ROOF LEAKING - WOOD CEILING ROTTEN ABOVE IN HALLWAY-NO SMOKE DETECTOR. NO MEANS OF EGRESS IN BEDROOM. WINDOWS BLOCKED BY STORAGE. KITCHEN SINK CONTROLS LOOSE AND UNSTABLE. BROKEN KITCHEN WINDOWS NO WEATHER SEALS AROUND. FRONT DOOR-BATHROOM SINK UNSTABLE AND NOT MOUNTED TO WALL. MISSING P.R. PIPE ON HW. HEATER NEED CONDUIT ON MAIN AND METER. WILL NEED ELECT. INSPECTOR TO SITE TO REVIEW METER HOOK-UPS. REF. TO DSD. ELECT. MAIN WORK W/O PERMITS. DOUBLE SHUT-OFF ON HW HEATER GAS. GAS (1) ALLOWED. WALL HEATER IS VERY OLD 20-30. WILL NEED NEW INSTALLED. UNIT VERY COLD. REF. TO DSD W/O PERMITS, PLUMBING ELECT., ROOM IN REAR. (UNIT MAY HAVE BEEN GARAGE). I CALLED OWNER WILL MEET BETWEEN 1-4 TODAY WITH MECH. PEOPLE TO REVIEW HEATER. |