Case: T02VL01870

Parcel: 124031760


Addresses:

422 N MARTIN AV


Inspection Status: Closed

Inspection History: FOLLOW UP CODE VIOLATION

Case Number - T02VL01870

Inspection Description - FOLLOW UP CODE VIOLATION

Inspection Status - Closed

Date Description Inspector Results Comments
06/11/2003 FOLLOW UP CODE VIOLATION Closed CASE WENT INTO CITATION. MIKE RANKIN WORKED OUT A DEAL WITH THE OWNER. ALL UNITS ARE VACANT. OWNER IS TRYING TO GET LOT REZONED FOR U OF A PARKING. CASE IS CLOSED.
12/04/2002 FOLLOW UP CODE VIOLATION Correction Required F/U INSPECTIOON SCHEDULED WITH ROB H., GLENN DE'AURIA, KETH FOSTER AND MARTIN ROMERO.
FOUND FRONT UNIT #A VACANT AND SECURED AT THIS TIME. UNABLE TO ENTER UNIT.
REAR UNIT #C IS VACANT AND SECURED. NOT ABLE TO ENTER INTERIOR OF UNIT.
STAIRWELL AT EASTEND THAT WAS IN VIOLATION HAS BEEN REMOVED. A NEW STAIRWELL HAS BEGUN BUT IS NOT COMPLETED AT THIS TIME.A PERMIT IS NECESSARY FOR REPAIRS.
CARPORT /PORCH AT NORTH END OF APT. #C HAS BEEN REMOVED. NO OTHER REPAIRS DONE TO APT. #C OR #A.
ENTERED APT. #B. NO REPAIRS HAVE BEEN DONE TO INTERIOR OR EXTERIOR OF THIS UNIT.
NO WORK TO BREEZEWAY BETWEEN APT. #A AND #C. NONE OF THE VIOLATIONS FROM SABER NOTICE HAVE BEEN ABATED AT THIS TIME. ROB H. WILL REFER CASE TO MIKE RANKIN FOR CITATION.
09/23/2002 FOLLOW UP CODE VIOLATION Correction Required INITIAL INTERIOR INSP WITH TFD AND ROB HENDRICKS. FOUND ILLEGAL DOUBLE KEYED DEAD BOLT CYLINDER FRONT DOOR. HOLES THROUGHOUT FLOOR IN HOME. ILLEGAL LIGHT FIXTURE OVER BATH SINK. EXPOSED WIRING CLOSET, CONVENIENCE OUTLET LIVING ROOM AND MECHANICAL ROOM.NO CONTROL KNOB AT RADIATOR HEATER. ALL WINDOWS IN SLEEPING AREAS MUST OPERATE PROPERLY.MISSING COOLER REGISTER IN BEDROOM.SMOKE DETECTOR DOES NOT OPERATE PROPERLY.STOVE VENT HOOD LACKS REQUIRED SCREEN. PRESSURE LINE AT WATER HEATER MUST BE EXTENDED TO THE EXTERIOR.FURNACE HAS NOT BEEN PROPERLY MAINTAINED. STACK VENT TO BOILER NOT SEALED AT WALL PENETRATION. NO EGRESS ESCAPE BACK ROOM AT ENCLOSED ADDITION.
09/23/2002 FOLLOW UP CODE VIOLATION Correction Required INITIAL INSP APT C. GFCI OUTLET REQUIRED OVER SINK IN BATHROOM. REQUIRED AGA SHUTOFF VALVE MISSING AT STOVE. ILLEGAL EXIT DOOR AT UPSTAIRS EXIT. RAIN GUTTER MUST BE PROPERLY SECURED TO OVERHANG. NO SMOKE DETECTOR UPSTAIRS BEDROOM. COOLER HAS NOT BEEN MAINTAINED PROPERLY. DOUBLE KEYED DEADBOLT CYLINDERS AT ALL EXIT DOORS. FURNACE HAS NOT BEEN MAINTATINED PROPERLY. GAS LINE NOT PROPERLY SECURED TO BUILDING LEADING TO FURNACE.
09/23/2002 FOLLOW UP CODE VIOLATION Correction Required INITIAL INSP APT B. EXPOSED WIRING IN HALLWAY. TRIPING HAZARD AT WATER LINE AT ENTRY DOOR TO HALLWAY. COOLER IS NOT PROPERLY WIRED. EXPOSED WIRING AT SUBPANEL EXTERIOR NORTH WALL. NOT ABLE TO ENTER APT B. TENANT WORKS NIGHTS AND WILL CALL INSP WHEN INSP CAN BE MADE.
09/20/2002 FOLLOW UP CODE VIOLATION Correction Required RECEIVED PHONE CALL FROM MR. PIERSON. SCHEDULED INSP FOR MONDAY 9/23/02 AT 9:00 AM