Inspection Status: Correction Required
Inspection History: INITIAL CODE VIOLATION
Case Number - T02VL01771
Inspection Description - INITIAL CODE VIOLATION
Inspection Status - Correction Required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/10/2002 | INITIAL CODE VIOLATION | Correction Required | 9/9/02, VISITED SITE, TOOK PICTURES, FOUND ONE TANK ON PROPERTY THAT NEEDED TO BE ENCLOSED, UPON LOOKING AT TANK FOUND THAT THE EXHAUST FLUE WAS INADEQUATE IN HEIGHT NEEDS TO EXTENDED TO 3' ABOVE ROOF LINE, PRESSURE RELIEF VALVE DRAIN ALSO NEEDS TO EXTENDED TO APPOX. 6'' ABOVE FLOOR, TALKED WITH OWNER BY PHONE AND EXPLAINED THE ISSUES AND HE STATED THAT HE WOULD HAVE REPAIRED BY END OF WEEK 9/14 OR 9/15/02 | |