Case: T02VL01678

Parcel: 129133180


Addresses:

903 E 35TH ST

Inspection Status: Compliance

Inspection History: FOLLOW UP CODE VIOLATION

Date Description Inspector Results Comments
12/06/2002 FOLLOW UP CODE VIOLATION Compliance CLOSE CASE VIOLATIONS ABATED.
11/01/2002 FOLLOW UP CODE VIOLATION Violation TFD-GLEN AND I REINSPECTED PROPERTY TODAY. AT THIS TIME THE OWNER IS 85% IN COMPLIANCE.
10/11/2002 FOLLOW UP CODE VIOLATION Correction Required ON 10/7/02, A SABER NOTICE WAS SENT OUT FOR BURNT PORCH IN UNSAFE CONDITION AT 901 AND ALSO FOR IT NOT BEING SECURED PROPERLY. AT 903 A NOTICE WAS SENT FOR#1) GARBAGE, JUNK AND DEBRIS#2) CARPORT AND STORAGE CONVERTED, #3) ROOF DETERIORATED WITHOUT A PERMIT, #4) THRESHOLDS MISSING, NO WEATHER STRIPPING,HOLES IN EXT. AND INT WALLS AND CEILING) #5) BATHROOM WALLS AND CEILING IN BAD SHAPE, #6) BATHTUB NOT DRAINING, LEAK AT BATHROOM SINK, #7) ELECTRICAL HAZARDS, #8) NO SMOKE ALARMS, #9) EGRESS HAZARDS, #10) hAZARDOUS MECHANICAL. A DETAILED NOTICE AND ORDER IS ON FILE AT DNR.
10/09/2002 FOLLOW UP CODE VIOLATION Violation 1. 901 UHC 1001.3, TFC 1101.2 - STRUCTUAL HAZARDS - #1 BURNT PORCH IS IN AN UNSAFE CONDITION. #1 REPAIR, REMOVE OR REPLACE INCLUDING SECURING OF ALL APPLICABLE PERMITS. (IF REQUIRED) BY DSD. IF A PERMIT IS REQUIRED A LICENSED CONTRACTOR WILL BE REQUIRED TO PERFORM THE CORRECTIONS.

2. 901 UCADB 302 DANGEROUS BUILDING- UNIT IS NOT SECURED PROPERLY FROM ALL ACCESS TO UNIT. #1 SECURE UNIT FROM UNAUTHORIZED ENTRY COMPLETELY AND TOTALLY.

3. 903 UHC 401 NUISANCE, #1 GARBAGE, JUNK, DEBRIS, AND WEEDS THROUGH OUT THE PROPERTY. #1 CLEAN AND REMOVE AS REQUIRED.

4. 903 UHC 301 UNSAFE AND UNPERMITTED CONSTRUCTION. #1 CARPORT AND STORAGE ROOM HAVE BEEN CONVERTED INTO LIVING SPACE. NO PERMITS ON RECORD FOR SUCH WORK. #1 CONSTRUCT BACK TO ORIGINAL STRUCTURE, REMOVE OR SECURE NECESSARY PERMITS FROM DSD PERMITTING SUCH CONVERSION.

5. 903 UHC 1001.8 FAULTY WEATHER PROTECTION, #1 THRESHOLDS MISSING AT BACK AND FRONT DOORS AND ARE NOT PROPERLY WEATHER-STRIPPED. #2 HOLES IN EXTERIOR AND INTERIOR WALLS AND CEILINGS. #3 ROOF IS DETERIORATING AND LEAKING THROUGHOUT THE UNIT. #1 INSTALL THRESHOLD AND WEATHER STRIP ACCORDING TO STANDARD PRACTICE. #2 PATCH AND SEAL ALL HOLES AND PENETRATIONS IN EXTERIOR AND INTERIOR. #3 REPLACE OR REPAIR AS REQUIRED BY CODE INCLUDING SECURING OF PERMITS AS REQUIRED BY DSD.

6. 903 UHC 1001.2.13 INADEQUATE SANITATION #1 BATHROOM WALLS AND CEILING HAVE NOT BEEN MAINTAINED SO AS TO RETAIN A NON-ABSORBENT AND SANITARY CONDITION. HOLES IN BATHROOM CEILING AND WALLS. MISSING OR DETERIORATED DRYWALL. #1 REPAIR AND REPLACE AS REQUIRED.

7. 903 UHC 505.7 HAZARDOUS PLUMBING, #1 BATHTUB WASTE PIPE DOES NOT FUNCTION PROPERLY. #2 LEAK AT BATHROOM SINK VANITY. #1 CLEAN, REPLACE, OR REPAIR DRAIN AS REQUIRED. IF REPLACEMENT IS NEEDED TO CORRECT VIOLATION, A PERMIT WILL NEED TO BE SECURED THROUGH DSD AND A LICENSED CONTRACTOR TO MAKE REPAIRS. 2. CLEAN, REPAIR, OR REPLACE AS TO WORK PROPERLY.

8. 903 UHC 701.3 ELECTRICAL HAZARDS- #1 SOME ELECTRICAL RECEPTACLES DO NOT WORK IN UNIT. #2 EXPOSED ELECTRICAL AT INTERIOR AND EXTERIOR OF HOME WITH FIXTURES HANGING DOWN. #1 HAVE LICENSED ELECTRICAL CONTRACTOR MAKE ALL REPAIRS AND CONFIRM THAT ELECTRICAL SYSTEM IS IN SAFE OPERATING CONDITION. SECURE PERMIT WITH DSD BEFORE WORK BEGINS. #2 REPLACE, REPAIR, OR REMOVE AS REQUIRED BY CODE.

9. 903 TFC 1001.5.1 FIRE PROTECTION #1 UNIT LACKS SMOKE ALARMS. #1 SMOKE ALARMS SHALL BE INSTALLED AND MAINTAINED IN GOOD WORKING.

10. 903 UHC 801 EGRESS #1 ALL WINDOWS IN SLEEPING ROOMS SHALL OPERATE UNLESS THERE IS A DOOR LEADING TO EXTERIOR FOR ESCAPE. #2 WROUGHT IRON SECURITY BARS ON BEDROOMS MUST BE BREAK A WAY FOR EASY ESCAPE. #1 REPAIR OR REPLACE AS NECESSARY. #2 REMOVE OR ALTER TO CODE.

11. 903 UHC 1001.7 HAZARDOUS MECHANICAL #1. COMBUSTION REGISTERS MISSING AT WATER HEATER. #2 FURNACE AND COOLER REQUIRE MAINTENANCE. #1 REPLACE OR REPAIR AS TO CODE 2. MAINTAIN IN SAFE WORKING CONDITION.
08/26/2002 FOLLOW UP CODE VIOLATION Correction Required SABER CASE #30.