Inspection Status: Correction Required
Inspection History: INITIAL CODE VIOLATION
| Date |
Description |
Inspector |
Results |
Comments |
| 08/20/2002 |
INITIAL CODE VIOLATION |
|
Correction Required |
BUILDING SECURE BUT NO PERMITS FOR REPAIR, FOLLOW UP 9/20/02 |
| 08/11/2002 |
INITIAL CODE VIOLATION |
|
Correction Required |
TPD EMERGENCY CALL. CAR HIT BUILDING. BEARING WALL & GAS SERVICE DAMAGED MINOR DAMAGE TO ELECTRIC SERVICE. POWER LEFT ON OWNER LEFT IN HOUSE. F.U. 5 DAYS. DAMAGE PICK UP TRUCK DAMAGE EAST WALL. BUILDING: 4' WIDE AND AGAIN UNDER WINDOW STUCCO, STUDS INTERIOR DRYWALL DAMAGE. ELECTRIC TRUCK HIT RISER TO SERVICE ENTRANCE PANEL INTACT BUT ELECTRIC INSPECTION REQUIRED BEFORE COVERING INTERIOR WALL WITH SHEETROCK. GAS LINE DAMAGED. NEW PRESSURE TEST REQUIRED. MECHANICAL N/A. SUMMARY OF REMARK PERMITS FOR FRAMING SHEETROCK, STUCCO ELECTRIC INTERMEDIATE ELECT FINAL AND GAS PRESSURE REQUIRED. |