Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Compliance
Inspection History: FOLLOW UP CODE VIOLATION
Case Number - T02VL00941
Inspection Description - FOLLOW UP CODE VIOLATION
Inspection Status - Compliance
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/13/2003 | FOLLOW UP CODE VIOLATION | Compliance | CASE CLOSED IS IN COMPLIANCE. | |
| 09/20/2002 | FOLLOW UP CODE VIOLATION | Approved | CECI SENT ME OUT TO CHECK IF SOMEONE WAS STEALING POWER FROM LAUNDRY ROOM. FOUND NO EXTENSION CORDS. PLACE IS STARTING TO ACCUMULATE GARBAGE AND DEBRIS AGAIN. | |
| 08/02/2002 | FOLLOW UP CODE VIOLATION | Approved | CONDEMNATION STATUS; CONFER WITH INSPECTOR II ROB HENDRICKS ON 8/02/02 REGARDING EXISTING VIOLATIONS ON THE PROPERTY, THE REENERGIZING OF THE SITE AND REHABITATION OF THE PROPERTY. BECAUSE OF THE HAZARDS AND THE COMPLICATIONS ASSOCIATED WITH THIS CASE MR. HENDRICKS WILL BE CONSULTING WITH APPROPRIATE STAFF ON MONDAY 8/5/02 FOR A ACTION PLAN. |
|
| 07/05/2002 | FOLLOW UP CODE VIOLATION | Violation | SITE VISITE I FOUND OWNER'S OF UNIT 11 SLEEPING IN P.U TRUCK-ELECT. WAS BACK ON-SHUT OFF AT METER BY INSPECTORS. UNIT 12 WAS SLEEPING INSIDE UNIT. DID NOT TAKE HOTEL FROM JUDY. SAME FOR UNIT 13. TOM STILL LIVING INSIDE. AROUND UNIT 11 I DID FIND OPEN TURPENTINE CAN OPEN INSIDE BUCKET. THE INSIDE OF BURN UNIT IS MISSING ICE BOX AND OTHER ITEMS THAT WERE THERE BEFORE FIRE. TPD CALLED TO SITE TO REMOVE 13 PEOPLE. C-6 AT SITE AND C-10 TWO VACANT UNITS REMAIN OPEN AFTER N.O.V. WAS RETURNED. T.P.D. AT SITE AT 12:00 NOON. WANTS TO INSPECT AT STIE. I RETURNED AT 12:30 PM. DEMO TEAM AT SITE W/OWNER-CLEAN-UP. | |
| 07/03/2002 | FOLLOW UP CODE VIOLATION | Violation | SITE VISIT I FOUND YELLOW DROP CORD RUNNING ACROSS DRIVEWAY TO A TENT-CAMPING ON LOT. ALSO THESE ARE NOW GAS METER'S WITH NO CAPS-CHAINLINK FENCE WAS REMOVED BY OWNER. THAT C.O.T. INSTALLED AROUND BURN UNITS. THERE IS MORE TRASH AND DEBRIS ON LOT. MORE USE OF DROP CORDS TO UNITS. NO SEWER LINES HAVE BEEN REPAIRED. CHILDREN PLAYING ON BURN TRAILER AT END. I CALLED OWNER AT 10:00 AM. ONWER STATED THAT I WAS HARRASSING HIM AND STARTED YELLING OBSCENITIES AT ME TELLING ME TO PUT ON SOME GLOVES AND CLEAN IT MYSELF. I STATED THAT THERE REMAINS HAZ. AT SITE. I TOLD HIM I WILL HAVE MY SUPERVISOR CONTACT HIM. SAME RESPONSE FROM OWNER. OWNER HUNG-UP PHONE ON ME. I CALLED C-6 TO MEET ME AT 12:00 NOON. ROB C-6 AT STIE. JUDY CALLED HEALTH DEPT. RALY MAJUTA AT STIE FOR ELECT. DEEMED HAZ. MAIN POLE OVERLOADED AND UNSTABLE. JUDY DOING PLACEMENT. RAY M. DID REPORT AT SITE. TEP CALLED TO REMOVE POWER 2:45 PM-PENDING C-6 FAX ORDER. | |
| 07/03/2002 | FOLLOW UP CODE VIOLATION | Violation | NEW PHOTO'S TAKEN | |
| 07/03/2002 | FOLLOW UP CODE VIOLATION | Violation | 1. MAIN 100A SERVICE INADEQUATE-PROVIDES SERVICE POORLY SUPPORTED-CHAINS USED TO SUPPORT SERVICE EMT CONDUIT RUN UNDERGROUND. 2. ELECTRICAL TIE AT UNIT #10 HAZARDOUS, COULD POSSIBLY CAUSE DAMAGE IF NOT REMOVED. 3. UNIT #4 GAS METER HAZARDOUSLY CLOSE TO ELECT BOX, MISSING PANEL ON UNIT HAZARDOUS. 4. EXTENSION CORD USE TO FEED VARIOUS MH'S HAZARDOUS. 5. RECEPTACLE ON SERVICE #11 BURNED OUT, IMPROPER SPLICED CORD 6. SOME UNIT IMPROPERLY TIED IN DIRECTLY TO POWER SOURCE. 7. VARIOUS ELECTRICAL SERVICES VERY INADEQUATELY SUPPORTED. DUE TO THE REASON OF INADEQUATE MAINTENANCE, DILAPIDATION, OBSOLESCENCE, FIRE HAZARD, THE CONTINUED USE OF THE ELECTRICAL DISTRIBUTION PRESENTS AN IMMINENT HAZARD. THE ELECTRICAL POWER SHOULD BE SHUT OFF AS SOON AS POSSIBLE TO PREVENT ANY PROBLEMS. UAC 94 SECTION 203 UNSAFE BUILDING SERVICE EQUIPMENT. |
|
| 07/03/2002 | FOLLOW UP CODE VIOLATION | Violation | PIMA HEALTH REPORT:OBSERVED R.V. TRAILER CONNECTIONS NOT PROPERLY FITTED (FLY TIGHT) OBSERVED SEWAGE ON GROUND UNDER 2 R.V. TRAILERS. OBSERVED GRAY WATER AND BLACK WATER FLOWING FROM AND POOLED BEHIND APARTMENTS, ALSO DETECTED A FOUL ODOR FROM THIS AREA. A N.O.V. WILL BE ISSUED TO PROPERTY. | |
| 06/27/2002 | FOLLOW UP CODE VIOLATION | Violation | UNITS REMAIN SECURED BY CHAIN LINK FENCE. POWER OFF TO BURN UNITS. CLEAN-UP PROCESS IS SLOW. | |
| 06/08/2002 | FOLLOW UP CODE VIOLATION | Violation | ON JUNE 8TH 02 THE CITY SECURE DMOBILE HOMES AT THE ADDRESS LISTED ABOVE DUE TO THE HAZARDOUS CONDITIONS POSED TO THE COMMUNITY. THE LACK OF COMPLIANCE BY THE OWNER HAS RESULTED IN REPEATED CALL-OUTS ASSOCIATED WITH THE HAZARDOUS MOBILE HOMES. THE BURNED AND OTHER PARTIALLY DISMANTLED MOBILE HOMES WHICH WERE SECURED BY THE CITY IS DEFINES AS A TEMPORARY REMEDY. A MORE PERMANENT ACTION IS REQUIRED BY THE OWNER. | |
| 05/20/2002 | FOLLOW UP CODE VIOLATION | Correction Required | 120 PHOTO'S TAKEN OF SITE. WAS HERE LAST WEEK. 13-TRAILERS, 3-HOUSES, 1-W/D ROOM, 4 SHEDS. TRASH AND DEBRIS. |