Case: T02VL00855

Parcel: 124171530


Addresses:

934 S SANTA RITA AV

Inspection Status: Approved

Inspection History: FOLLOW UP CODE VIOLATION

Date Description Inspector Results Comments
10/03/2003 FOLLOW UP CODE VIOLATION Approved FOLLOW UP: RICK S, ENTRY:
10/03/03: CONDUCTED RE-INSPECTION OF PROPERTY IN ORDER TO ASSESS C.C.D. PARTICIPATION AND WALLS SHOWING MOVEMENT. PEOPLE ON SITE WERE KAT, RICHARD V., HAROLD P., HECTOR L. AND RICK S.

STRUCTURALLY FOUND THERE WERE FOOTINGS UNDER ADOBE STRUCTURE. THIS DOES STRENGTHEN CASE THAT BLOCKS USED ON SOUTH WALL ARE ACTING AS SUPPORTS. IT DOES APPEAR A LOT OF THE EROSIAN ON THE NORTH WALL IS COMMING FROM THE INCORRECT MANNER IN WHICH THE WASHER HOOK UP WAS MADE. C.C.D. DID BELIEVE THAT BECAUSE OF THE STRAIGHT ROOF LINE ON THE NORTH SIDE WALL WAS EVIDENCE OF THE WALL NOT SINKING AT THIS TIME. THEY ALSO BELIEVED THAT THE GAP BETWEEN THE CIELING & EAST WALL (NON-BEARING) WAS DUE TO SHRINKAGE OF CIELING RATHER THAN EASTWARD MOVEMENT OF THE WALL. RICHARD & HAROLD DID CONCUR WITH RICK'S ESTIMATE THAT IF EITHER SOUTH OR NORTH WALL WERE TO GIVE OUT, THAT THE COLLAPSE WOULD BE IN A DOWNWARD DIRECTION AS OPPOSED TO A HORIZONTAL DIRECTION. IN ADDITION THE TOP PLATE & ROOF ASSEMBLY WOULD NOT ALLOW F0R A COMPLETE CAVE IN OF THE ASSOCIATED ROOMS. THIS SITUATION ONLY RMOVES THE DEFINITION OF IMMEDIATE HAZARD BUT NOT IMMANAENT HAZARD. DNR WILL ALLOW C.C.D. TO CONTINUE WITH ASSISTANCE PROCESS IN RELATION TO ADDRESSING STRUCTURE. DNR WILL ISSUE N & O THAT WILL ALLOW SUFFICIENT TIME FOR C.C.D. TO QUALIFY OWNERS BUT WITHIN TIME FRAME THAT WOULD ALLOW DNR TO RE-ASSESS AS TO DIRECITON OF CASE AND CONDITION OF STRUCTURE AT THAT TIME. IF C.C.D. COMMENCES WORK THEN THEY TO ADDRESS WALLS. IF THEY DO NOT, THEN DNR WILL REQUIRE IN-DEPTH ASSESSMENT, APPROPRIATE ACTION WHICH MAY RESULT IN THE VACATING OF THE UNIT IF NECESSARY.

CECI AND HECTOR TO DISCUSS WITH MELISA AND KAT THE OWNERSHIP SO AS TO BE ABLE TO ISSUE NOTICE AND ORDER. C.C.D HAS BEEN WORKING WITH LAWYER OF CURRENT PEOPLE OCCUPYING THE HOUSE. THEY ARE STATING THEY ARE OWNERS AND HAVE SUBMITTED PAPERWORK TO C.C.D. THE LEGAL ASSESORS OFFICE SHOWS OWNERS IN CALIFORNIA.
10/03/2003 FOLLOW UP CODE VIOLATION Correction Required VISITED SITE, PRESENT WERE 2 INSPECTORS FROM C.C. & D., INSP. VIDAL AND INSP. POOLE AND KARLA. INSP. VIDAL AND POOLE DID AGREE THAT WALLS ARE AN EMINATE HAZARD AND SHOULD HAVE STRUCTURAL ENGINEER ACCESS INTEGRITY OF ALL ADOBE WALLS. REQUESTED NOV NOT TO BE ISSUED TILL OWNERSHIP IS RESOLVED NEXT WEEK 10/06/03, ALL AGREED AFTER OWNERSHIP IS RESOLVED A NOTICE WILL BE ISSUED FOR STRUCTURAL HAZARDS AND WILL ALLOW 15 DAYS TO SECURE DOCUMENTATION FROM STRUCTURAL ENGINEER.
10/02/2003 FOLLOW UP CODE VIOLATION Correction Required VISITED SITE: MET WITH ONWER AND INSP. RAY CAMACHO, WENT OVER DETERIORATION OF ADOBE BLOCK WALLS THROUGHOUT STRUCTURE. INSP. CAMACHO DID AGREE THAT DETERIORATED SECTION OF WALLS WERE AN IMMINENT HAZARD AND DANGER OF COLLAPSING EVENTUALLY. INSPECTION OF NORTH WALL WAS DETERMINED THAT 30% OF BEARING WALL WAS IN DNAGER OF COLLAPSING AND DAMAGE TO THIS WALL WAS MORE EXTENSIVE THAN SOUTHWEST WALL. AGREED THAT TEMPORARY SHORING AT SOUTHWEST WALL WILL WORK FOR NOW BUT NEEDED TO BE SHORED UP PROPERLY. MET WITH INSP II RICK SALDATE, PRESENT WERE INSP. H. LOPEZ AND R. CAMACHO. DISCUSSION OF ADOBE STRUTURE AT 934 S SANTA RITA AVE WAS DISCUSSED. ALL WERE IN AGREEMENT THAT STRUCTURE SHOULD BE ISSUED A NOTICE AND GIVEN A 15 DAY ABATE OF VIOLATION ORDER AS WELL AS HAVE PROPER SHORING AND HAVE STRUCTURAL ENGINEER GIVE ASSESSMENT OF STRUCTURE BEARING WALLS. FINDING OF NORTH WALL HAVING A VOID OF 30% WAS A BIG CONCERN. WILL MAKE DETERMINATION ON MOVING FORWARD WITH NOTICE AFTER SCHEDULED MEETING WITH C.C. & D. PROGRAM.
09/29/2003 FOLLOW UP CODE VIOLATION Correction Required VISITED SITE: MET WITH OWNER INSP. II RICK SALDATE WAS PRESENT. EXTENSIVE DETERIORATION OF EXTERIOR WALLS THROUGH OUT STRUCTURE, WALLS ARE MADE OF ADOBE. FRONT PILLARS ALSO SHOW EVIDENCE OF DETERIORATION. NORTH BEARING WALL IS CRACKED APROX. 10' LONG UNDERNEATH WINDOW. 3" X 4" HOLE THROUGH WALL. PLASTER ON POSSIBLE ADDITION OF BATHROOM WALL IS FALLING AWAY AND EXPOSING 1" LATTACE. 3' HOLE UNDER KITCHEN WINDOW EXTENDS APPROX 4' X 3' ADOBE IS CRUMBLING AND DETERIORATED BADLY. COULD BE CONSIDERED 30% DETERIORATION OF BEARING WALL. ALTERATION TO SEWER DRAIN VENT PIPE HAS BEEN EXTENDED UP UNDERNEATH OVERHAND OF ROOF AND 8' OUT WITH 6' AWAY TO THE BACK OF YARD AND IS ALLOWING GRAY WATER TO PUDDLE AND STAND ON PROPERTY. WEST WALL HAS APPROX 4' X 6' SECTION OF PLASTER THAT HAS FALLEN AWAY EXPOSING 1" X 3/8" WOOD LATTACE AND CHICKEN WIRE. REAR DOOR IS BADLY DELAPIDATED AND HAS EXTENTION CORD RUNNING THROUGH FOR COOLER SWITCH (HAZARDOUS ELECTRICAL) UNDER DOOR ADOBE WALL HAS DETERIORATED TO A POINT OF COLLAPSING, HAS 6" X 4" WOOD BRACING DOOR, SOUTHWEST END OF STRUCTURE HAS DROPPED APPROX. 3" AND HAS HOLE APPROX. 2' X 4' BELOW WINDOW FRAME. WINDOW FRAME IS LISTING APPROX. 3" X 36" CINDER BLOCKS WITH CAP BLOCK HAVE BEEN INSERTED TO ACT AS TEMPORARY BRACING. SEVERAL STRESS CRACKS EXTEND THROUGH NORTHWEST BEARING WALL. WINDOW IS COVERED WITH PLASTIC IN LIEU OF WINDOW PANE. ELECTRICAL DISCONNECT BOX IS ORIGINAL AND MAYBE 60 AMP, WEATHER HEAD IS UNDER OVERHANG AND MOUNTED ON 10 X 20 3/4 PLYWOOD BOARD AND IS COMING AWAY FROMS STRUCTURE. HAZARDOUS ELECTRICAL CONDUCTORS ARE SPLICED AT WEST BEDROOM CEILING LIGHT FIXTURE AND GOES TO COOLER SWITCH. WOOD BURNING STOVE IN WEST BEDROOM IS USED FOR HEAT AND IS NOT TO CODE, FLUE PIPE SYSTEM IS NO B-VENT TYPE AND PENETRATION OF FLUE VENT THROUGH CEILING REST AGAINST ROOF TRUSSES. SEVERAL SECTION OF WOOD FLOOR ARE LOOSE THROUGHOUT STRUCTURE. POSSIBLE ADDITION OF BATHROOM WALLS ARE CRACKED AND CRUMBLING AND NOT FINISHED. TUB LACKING FAUCET HARDWARE AND CAN BE TRUEND ONLY BY USE OF PLIERS. BATHROOM TUB AND TOILET IS HOOKED UP TO SEPTIC AND NOT CONNECTED TO PUBLIC SEWER SYSTEMS AND IS EVIDENCE BY RECORDS AT PIMA COUNTY WASTE WATER. STRUCTURE IS SUPPLIED WITH PROPANE GAS SERVICE. INTERIOR LIVING ROOM SOUTHEAST CORNER HAS SEVERE WATER DAMAGE AND HAS CAUSED CIELING TO BUCKLE. DETERIORATION OF ADOBE WALLS HAS CAUSED CEILING TO SEPERATE APPROX. 1 1/2 AWAY FROM WALL. FRONT DOOR FRAME HAS RAISED 1" OFF FLOOR. LIVING ROOM HAS VERY OLD TYPE GAS LOG HEATER AND IS LACKING VENT SYSTEM. SEVERAL LOCATION THROUGHOUT INTERIOR CIELING HAS BEEN DAMAGED BY WATER LEAKING THROUGH ROOF. APPROX 4' X 4' TARP HAS BEEN USED TO COVER LEAKING ROOF AREA. SEVERAL CARS AND TRUCKS ARE PACKED IN BACKYARD. TENANT INFORMED US OF INTER ACTION WITH C.C. & D AND HAVE QUALIFIED FOR PROGRAM THAT WILL HELP WITH REPAIRS. WILL CHECK WITH CAT AT CC & D FOR VERIFICATION OF PROGRAM AND STATUS BEFORE MOVING FORWARD. PICTURES WERE TAKEN. CONTACTED CAT AT CC & D PICTURES WERE SHOWN TO INSP. RICHARD VIDAL AND HAROLD POOLE. IT WAS DECIDED THAT INSP WILL BE REQUIRED BY HAROLD POOLE FOR APPROVAL TO CONTINUE ASSISTANCE PROGRAM. DECISION TO POSSIBLY SHUT DOWN STRUCTURE WILL DEPEND ON MEETING SCHEDULED FOR 10/03/03. WILL ATTEMPT TO CONTACT D.S.D. FOR STRUCTURAL ASSESSMENT BY ONE OF THEIR INSPECTORS.
09/29/2003 FOLLOW UP CODE VIOLATION Correction Required HECTOR TOOK RICK SALDATE TO SITE IN ORDER TO ASSESS STRUCTUREAL CONCERNS OF ADOBE HOUSE. INSPECTION FOUND HEAVY DETERIORATION OF 2 EXTERIOR BEARING WALLS (NORTH AND SOUTH) ONE OF WHICH IS IN REAR BEDROOM AND OTHER IN FRONT LIVINGROOM. OWNERS STATED OWNERSHIP IN PROCESS OF TRANSFER AND THEY ARE WORKING WITH KARLA TIMMONS OF CCD. RICK AND HECTOR MET WITH KARLA AND HAROLD POOLE, REVIEWING PICTURES HECTOR TOOK ON SITE. CCD STATED THAT IF WE CONDEMN STRUCTURE, THEN CASE WOULD FALL APART AND URGED US NOT TO CLOSE. KARLA HAD BEEN ON SITE AND SAW THE WALLS BUT HAROLD HAD NOT. AS A GROUP WE REVIEWED THE PICTURES IN ODER TO HAVE CCD INFORM US OF THIER ASSESSMENT OF THE WALLS. THIER READ OF THE SOUTH WALL WAS THAT THE BLOCKS PLACED INSIDE OF THE DETERIORATED PORTION WAS SUFFICIENT TO ACT AS SUPPORT. CCD (KARLA, RICHARD AND HAROLD) TO MEET RICK AND HECTOR ON SITE TO ASSESS CCD CASE (FRIDAY) AND TO UTILIZE HAROLD TO GIVE PRELIMINARY STRUCTURAL ASSESMENT. COVERSATION WITH KARLA STATED THAT HE IS PERSON CCD USES IN SUCH A MATTER AS THEY PUT TOGETHER THIER CASES. ACTION: WILL REVIEW CASE WITH HECTOR ON FRIDAY AFTER MEETING WITH CCD. DEPENDANT ON OUTCOME, DSD MAYBE CALLED IN TO GAIN FINAL STRUCTURAL INTEGRITY. F/U 10/03/03
09/26/2003 FOLLOW UP CODE VIOLATION Correction Required VISITED SITE, NO ONE HOME MADE CONTACT WITH TWO NEIGHBORS, UNKNOWN IF TENANT IS RENTING 1- STATES LISTED PERSON ON ASSESSOR'S PAGE IS STILL OWNER. OWNER MAY HAVE LET TENANT STAY AS LONG AS PROPERTY AND MAYBE HOMESTEADING PROPERTY. MAYBE BE USING PROPANE, STRUCTURE SHOWS EVIDENCE OF STRUCTURAL PROBLEMS LARGE CRACKS AND IS LEANING TO ONE SIDE REPORTS FROM NEIGHBORS STATES ROOF LEAKS INSIDE. EVIDENCE OF GRAY WATER PUDDLING ON PROPERTY 2' PVC PIPE EXTENDS FROM STRUTURE APPROX. 8' MAYBE HOOKED UP TO SEPTIC TANK, EXTENTION CORD COMING OUT FROM BACK DOOR, UNABLE TO IDENTIFY LOCATION. NO GAS METER SEEN ON PROPERTY AND SEEMS TO HAVE ELECTRICAL SERVICE ATTACHED TO SOUTH SIDE OF STRUCTURE.
05/01/2002 FOLLOW UP CODE VIOLATION Correction Required GOT 2-SMOKE DETECTOR FROM T.F.D. AND GAVE TO TENANT. TENANT WILL INSTALL. WAS UNABLE TO FIND RECORDS ON PROPERTY AND WAITING FOR RESULT FROM WASTE WATER IF LATERAL LINE IN TIED TO MAIN SYSTEM.
04/30/2002 FOLLOW UP CODE VIOLATION Correction Required VISITED SITE AND MET WITH TENANT AND HOUSE HAS UTILITIES. HOUSE IS IN NEED OF REPAIRS. DID CHECK THRU OUT HOUSE AND HAS WHERE BATHROOM HAS BEEN ADDED OR REPAIRED. HAS NO SMOKE DETECTORS. WILL GET FROM TFD. WILL DO RESEARCH ON PROPERTY. CALLED WASTE WATER AND HAS NO RECORDS IN CITY SIDE. PULLED G.I.S. AND ADDRESS IS TIED TO OTHER ADDRESS. WILL KEEP TRYING TO FIND RECORDS.