Inspection Status: Correction Required
Inspection History: INITIAL CODE VIOLATION
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/04/2002 | INITIAL CODE VIOLATION | Correction Required | H-301: HEATER ENCLOSURE ATTACHED TO REAR WALL. NEW PVC WATER LINES AND GAS LINES CONNECTED TO WATER HEATER. NEW PLUMBING VENT INSTALLED TO REAR WALL BY KITCHEN. LACKS REQUIRED PERMITS. H-505.7: LEAK AT KITCHEN FAUCET FIXTURE. H-601.2: ALL EXTERIOR DOORS, LACK PROPER WEATHER STRIP AND SWEEPS. ACCESS PANEL TO ATTIC AT KITCHEN CEILING MUST BE PROPERLY SEALED. UPC SEC 1007:TEMPERATURE AND RELIEF VALVE MUST BE EXTENDED TO THE EXTERIOR. H-701.1: THE HEATING FACILITIES HAVE NOT BEEN MAINTAINED PROPERLY. WALL HEATER ENCLOSURE MUST BE SECURED. H-701.3: ALL INTERIOR CONVENIENCE OUTLETS TEST OPEN GROUND. A REQUIRED GFCI OUTLET IS LACKING OVER BATHROOM SINK. LIGHT FIXTURE OVER BATH SINK LACKING AT FRONT ENTRY DOOR. H-901: THE UNIT LACKS THE REQUIRED SMOKE DETECTOR. (1) H1001.12: THE FRONT ENTRY DOOR IS OF INADEQUATE DIMENSION FOR ESCAPE AND RESCUE. MUST BE 36" OR LARGER. WINDOW SILL HEIGHT IN BEDROOM HIGHER THAN 44". TFC 901.4.4: ADDRESS NUMBERS MUST BE PLAINLY VISIBLE FROM STREET. |