Case: T02VL00761

Parcel: 140231840

Inspection Status: Correction Required

Inspection History: INITIAL CODE VIOLATION

Date Description Inspector Results Comments
04/02/2002 INITIAL CODE VIOLATION Correction Required H-301: WATER HEATER ENCLOSURE ATTACHED TO REAR EXTERIOR WALL. PLUMBING FIXTURES ADDED FOR WASHING MACHINE MUST BE PERMITTED OR DELETED. PERMITS REQUIRED.
H-505.4: BATHROOM WALLS HAVE NOT BEEN MAINTAINED SO AS TO RETAIN A NON-ABSORBENT AND SANITARY CONDITION.
H-505.7: BATHROOM VANITY COUNTER TOP IS NOT PROPERLY SECURED TO WALL.
H-601.2: ALL EXTERIOR DOORS, LACK PROPER WEATHER STRIP AND SWEEPS.
UPC SEC 1007: TEMPERATURE AND RELIEF VALVE MUST BE EXTENDED TO THE EXTERIOR.
H-701.1: THE HEATING FACILITIES FOR THE DWELLING HAS NOT BEEN MAINTAINED PROPERLY.
H-701.3: THE REQUIRED LIGHT FIXTURE AT FRONT ENTRY DOOR IS MISSING. LIGHT FIXTURE OVER BATH SINK MUST BE OF PROPER TYPE OR GFCI DELETED. DWELLING LACKS PROPER ELECTRICAL CONNECTION FOR WASHING MACHINE. EXTENSION CORD FROM BEDROOM BEING USED AT THIS TIME. A PERMIT MUST BE PULLED OR DELETED.
H-801: WINDOW IN BEDROOM IS NOT SUFFICIENT SIZE FOR EMERGENCY RESCUE OR ESCAPE. SILL HEIGHT EXCEEDS 44" MAXIMUM HEIGHT.
H-901: THE UNIT LACKS THE REQUIRED SMOKE DETECTOR. (1)
TFC 901.4.4: ADDRESS NUMBERS MUST BE PLAINLY VISIBLE FROM STREET.