Inspection History Details
Inspection Status: Approved
Inspection History: INITIAL CODE VIOLATION
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2009 | INITIAL CODE VIOLATION | Approved | ||
| 04/02/2002 | INITIAL CODE VIOLATION | Correction Required | H-301: DWELLING HAS BEEN CHANGED TO TWO-BEDROOM UNIT WITH COOLER. PULL REQURIED PERMITS WITH DRAWINGS. H-505.7: BATH FIXTURES AT TUB MUST BE PROPERLY SECURED. H-601.1: EXTERIOR OVERHANG IS DILAPIDATED AND IN NEED OF REPAIR. KITCHEN CABINET DOORS AND DRAWERS ARE MISSING AND IN NEED OF REPAIR. H-601.2: ALL EXERTIOR DOORS, LACK PROPER WEATHER STRIP AND SWEEPS ALL EXTERIOR AND INTERIOR DOORS MUST WORK PROPERLY WITH PROPER HARDWARE. INTERIOR DOOR JAMBS HAVE NOT BEEN MAINTAINED PROPERLY AND MUST BE REPLACED IN BEDROOM. H-701.1: THE HEATING FACILITIES FOR THE DWELLING ARE IN A HAZARDOUS CONDITION AND INOPERATIVE. H-701.2: THE EXISTING EVAPORATIVE COOLER IS NOT PROPERLY WIRED. HAS EXPOSED WIRING, MUST BE HARD WIRED TO PREVENT PHYSICAL DAMGE. COOLER STAND IS NOT PROPERLY SECURED TO WALL. H-701.3: CONVENIENCE OUTLET AT EXTERIOR DOOR DOES NOT FUNCTION PROPERLY. MAIN ELECTRICAL SERVICE PANEL IS NOT PROPERLY SEALED. KNOCKOUTS MUST BE REPLACED PER NEC. MAIN ELECTRICAL NOT EXTERIOR TYPE FOR WEATHER PROTECTION. H-801: ALL WINDOWS MUST OPERATE PROPERLY TO ALLOW PROPER EGRESS FOR EMERGENCY ESCAPE OR RESCUE WITHOUT THE USE OF SEPERATE TOOLS. H-901: THE UNIT LACKS THE REQUIRED SMOKE DETECTOR. (1) H1001.7: DWELLING LACKS REQUIRED REGISTERS AT COOLER DUCTWORK. TFC 901.4.4: ADDRESS NUMBERS MUST BE PLAINLY VISIBLE FROM STREET. |