Inspection History Details
Inspection Status: Correction Required
Inspection History: FOLLOW UP CODE VIOLATION
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/30/2003 | FOLLOW UP CODE VIOLATION | Correction Required | ATTENDED COURT WITH MS. SITA & INSP.II RICK SALDATE. RESPONDENT DID NOT APPEAR. RESPONDENT WAS FOUND NOT TO BE IN COMPLAINCE AND WAS FINED 10,000.00 $ FOR FAILURE TO ABATE REMAINING VIOLATIONS. CASE WAS REFERRED TO PROSECUTOR OFFICE. REMAINING VIOLATION WERE HARARDOUS PLUMBING, EXPIRED ELECTRICAL AND W/O/P ILLEGAL CONVERSION OF CARPORT INTO HABITABLE DWELLING. | |
| 06/16/2003 | FOLLOW UP CODE VIOLATION | Correction Required | RESPONDENT DID NOT APPEAR. MS. SITA & INSP. LOPEZ APPEARED. CITY AGREED TO GIVE RESPONDENT A 14 DAY EXTENTION. MOTION WAS GRANTED. ALL PARTIES ARE ORDERED TO APPEAR AT 3:30 PM JUNE 30 2003 | |
| 04/02/2003 | FOLLOW UP CODE VIOLATION | Correction Required | COURT: OWNER HAD EMERGENCY OUT OF TOWN, DEATH IN THE FAMILY. OWNER ASKED FOR CONTINUANCE. CONTACTED VIOLA, SHE CALLED IN SICK, WILL NOT BE ABLE TO APPEAR. PROSECUTED AGREED TO A CONTINUANCE FOR NEXT WEEK. CONTACTED OWNER-INFORMED HIM CONTINUANCE WAS GRANTED & WILL MEET ON SITE ON 4/4/03 TO GO OVER REMAINING VIOLATIONS TO BE ABATED |
|
| 03/03/2003 | FOLLOW UP CODE VIOLATION | Correction Required | FOLLOW UP: FOLLOW UP RE INSPECTION: HECTOR LOPEZ CONDUCTED FOLLOW UP INSPECTION RE COMPLIANCE FOR COURT TODAY. OWNER WAS ON SITE. WAS IN COMPLIANCE IN THAT HE SECURED GAS LINES, INSTALLED HOT WATER HEATER ENCLOSURES AND REMOVED PORCH. IN ADDITION HE HAS PAINTED STRUCTURE, REPLACED ROTTED FACIA. NOTE: OWNER WILL BE ADDRESSING HOT WATER PERMITS ON NEXT INSPECTION DATE. |
|
| 03/03/2003 | FOLLOW UP CODE VIOLATION | Correction Required | FOLLOW UP: VISITED SITE AND MET WITH OWNER. WENT OVER ITEMS REQUESTED BY COURT. HAS REMOVED PORCH HAS SECURED GAS PIPING ON REAR OF STRUCTURE. REPALACED ALL DETERIORATED FACIA BOARD.STRUCTURE HAS BEEN PAINTED. |
|
| 01/31/2003 | FOLLOW UP CODE VIOLATION | Correction Required | FOLLOW UP RE INSPECTION: INSPECTION CONDUCTED BY RICK S. AND HECTOR L. NUMBERS ASSOCIATED WITH VIOLATION NUMBERS ON ORIGINAL NOTICE AND ORDER ISSUED TO ART APODACA THEN TRANFERRED TO MR. CAMPAS. 1) NON COMPLIANCE DUE TO PERMITS NOT BEING FINALED. UNKNOWN HOW OR IF THE CIRCUITS OF THE MIDDLE ILLEGAL UNIT WERE ADDRESSED. NOTE; THE OLD MAIN SERVICE BOX IS NOW BEING USED AS A JUNCTION BOX. SOME OF THE INSIDE HAS BEEN REMOVED BUT NOT ALL. ALSO THE BOX IS OPEN. THIS ISSUE WOULD HAVE BEEN CHECKED BY THE ELECTRICAL INSPECTOR DURING THE INSPECTIONS ASSOCIATED WITH THE ELECTRICAL PERMIT. 2) NON COMPLIANCE. 3) UNIT-3: COMPLIANCE FROM INSPECTION DATED 06/18/02. 4) UNIT-5: COMPLIANCE. 5) UNIT 5: NON COMPLIANCE DUE TO INABILITY TO GAIN ENTRY. 6) UNIT-5: UNKNOWN DUE TO INABILITY TO GAIN ENTRY. 7-9) NON COMPLIANCE DUE TO OWNER RELAYING THAT HE HAS NOT CONVERTED UNIT AND PERMITS PLUS SHOW NO PERMITS SECURED RE ANY WORK ASSCIEATED WITH UNIT. 10) UNIT-7: COMPLIANCE FROM 06/18/02 INSPECTION. 11) UNIT-7: UNKNOWN DUE TO INABILITY TO GAIN ENTRY. 12) UNIT-7: UNKNOWN DUE TO INABILITY TO GAIN ENTRY. 13-14) UNIT-7: NON COMPLIANCE. 15) UNIT-7: UNKNOWN DUE TO INABILITY TO GAIN ENTRY. |
|
| 01/31/2003 | FOLLOW UP CODE VIOLATION | Correction Required | COURT: VIOLA, RICK AND HECTOR. OWNER FOUND IN VIOLATION AND NEW COURT DATE ON 03/03/03 AT 10:00AM. SCHEDULED FOR NEW COMPLIANCE HEARING. OWNER GIVEN THREE VIOLATIONS TO CORRECT (SECURE GAS LINES, PERMIT AND REPAIR HOT WATER. ADDRESS FRONT PORCH) BY NEXT COURT HEARING. OWNER WILL GET WITH INSPECTOR NEXT WEEK TO WORK OUT COMPLIANCE SCHEDULE. |
|
| 06/18/2002 | FOLLOW UP CODE VIOLATION | Correction Required | COMPLIANCE INSPECTION OF N & O: ON SITE INSPECTORS WERE RICHARD VIDAL, HECTOR LOPEZ AND JIM HURD. INITIAL N & O USED AS REF FOR VIOLATION NUMBERS. # 1-2: VIOLATION. # 3: COMPLIANCE. # 4-6: VIOLATION. # 7-9: COMPLIANCE(UNIT IN PROCESS OF BEING ELIMINATED AND COMBINED WITH UNIT-B. # 10: COMPLIANCE. #11-12: VIOLATION. # 13: COMPLIANCE. # 14-15: VIOLATION. OWNER RELAYED THAT HE IN PROCESS OF PREPARING PLANS WITH HE ANTICIPATES SUBMITTING TO DSD WITHIN 2-3 WEEKS. AFTER CORRECTIONS HE WILL SELL TO ONE OF THE OCCUPANTS. |
|
| 05/30/2002 | FOLLOW UP CODE VIOLATION | Correction Required | SUMMARY OF VIOLATIONS: UNIT #1 EXPOSED ROMEX IN KITCHEN 3 PRONG DUPLEX OUTLETS THRU OUT MAY NOT BE GROUNDED. FURNACE NOT WORKING AND NEED SERVICE HAZARDOUS ELECTRICAL IN BEDROOM COOLER SWITCH AND LIGHT FIXTURE. DOUBLE DEAD BOLT ON FRONT DOOR LACK OF WEATHER STRIPPING AND THRESHOLD. NO SMOKE ALARM. PERMITS-MAIN REPLACEMENT:WATER DISTRICT-EXPIRED STATUS-APPROVED 6/5/97 SAME DATE APPLIED AND ISSUED. T.D. 4-63-50 PERMIT APPLIED FOR GAS PIPING 11/15/68 AND FINALED 10/10/69. EXCAVATION PERMIT 6/04/86. T.D. 2-85-35 13 W DISTRICT ST SECTION M 1502 ICBO. SHALL NOT TERMINATE IN ATTIC. UNIT #2 NO THRESHOLD FRONT DOOR. 10" X 8" BEHIND STOVE WALL IN DISREPAIR. NO SMOKE ALARMS FURNACE NOT WORKING AND HAS NOT BEEN SERVICED. BATHROOM EASTWALL BAD CASE OF MOLD. BROKEN WINDOW IN KITCHEN. UNIT 3 WALL FURNACE NOT WORKING KITCHEN DUPLEX OUTLET 3 PRONG REST ARE 2 PRONG KITCHEN WINDOW HAS LATCH BROKEN KITCHEN LIGHT HAS NO PULL CHAIN (BROKEN) INSIDE OF BURNER HAS NOT BEEN SERVICED LOTS OF LINT. HOLE IN WALL BY BATHROOM NO SMOKE ALARM NO PRIVACY LATCH IN BATHROOM DOOR. UNIT #5 BLOCK OFF WINDOW ON NORTH WALL IN KITCHEN CEILING IN DISREPAIR BEDROOM MISSING TILES IN SHOWER BROKEN WINDOW SHOWER STALL WEATHER STRIPPING FRONT DOOR ALSO NO GLASS ON OPENING 6' X 20' ON FRONT DOOR. RANGE VENT-NO GRILL ABOVE STOVE NO SMOKE ALARMS. UNIT #6 WINDOW BLOCKED OFF IN BEDROOM DOOR BLOCKED OFF FROM UNIT #7. EXPOSE ELECTRICAL IN KITCHEN ON NORTH WALL 2 BOXES. BATH ROOM DOOR OPENS TO KITCHEN NO SEAL FOR SANITATION. BATHROOM SHOWER MISSING HANDLES AND BAD MOLD PROBLEM. UNIT HAS NO HEAT UNIT WAS CARPORT AND WAS TURNED INTO LIVING SPACE. BATHROOM WALL EASTSIDE IN DISREPAIR 2" HOLES ALONG BOTTEM. EXPOSED ELECTRICAL BOX BY BED NO COVERS NO SMOKE ALARM. UNIT #7 FASCIA WEATHER BEATEN SEWER CONNECTION FOR WASHING MACHINE POWER FOR WASHING MACHINE THRU WINDOW. NO WEATHER STRIPPING AND THRESHOLD REAR DOOR. CEILING IN KITCHEN IN DISREPAIR WEATHER STRIPPING LACKING FRONT DOOR AND DOOR NEEDS REPLACING OR REPAIRING WITH THRESHOLD. HOLES IN WALL BEDROOM. WINDOW BLOCKED IN BEDROOM. CEILING DAMAGE IN HALL CLOSET. BATHROOM DOOR IN DISREPAIR AND SPLINTERED. BROKEN WINDOW IN BATHROOM. NO SMOKE ALARMS. |
|
| 05/09/2002 | FOLLOW UP CODE VIOLATION | Correction Required | TRACK DOWN NEW OWNER. CAP MISSING FROM TOP OF SERVICE PANEL (EXISTING) UPGRADE. ELECTRICAL 60 AMP TO 200 AMP (T02VL00487) APPLIED APPROVED AND ISSUED 3/25/02 PERMIT #T02VL00487. NEW SERV. PANEL HAS BEEN INSTALLED. GAS AND WATER BONDING HAVE BEEN COMPLETED ALONG WITH GROUNDING RODS. NEW SMOKE ALARMS INSTALLED. NEW FACSIA AND DRIP EDGE. NEW MASTIC HAS BEEN APPLIED ROOF EDGE AND SEALED WORK WITHOUT PERMITS. ENCLOSED CONVERTED CARPORT IS BEING ADDRESSED. PLANS ARE BEING DRAWN UP. 3 WINDOWS HAVE BEEN REPLACED. FIRE HAZARD FOR UNIT 6 CONVERSION IS BEING ADDRESSED ALSO ELECTRICAL WORK BEING DONE BY HOLTON ELECTRIC. EXTENTION CORD FOR WASHING MACHINE HAS BEEN REMOVED. | |
| 03/15/2002 | FOLLOW UP CODE VIOLATION | Correction Required | VISITED SITE WITH INSPECTOR VIDAL CHECKED GAS PIPE BONDING, WATER BONDING AND GROUND ROD INSTALLATION. ALL HAVE BEEN COMPLETED. 3 NEW SMOKE ALARMS HAVE BEEN INSTALLED. #6 UNIT HAS BEEN VACATED AND FUSE PROTECTION HAS BEEN ADDED FOR UNIT. WILL UPDATE ELECTRICAL INSPECTOR, SHUT DOWN OF UNIT WILL NOT BE NEEDED. | |
| 03/15/2002 | FOLLOW UP CODE VIOLATION | Correction Required | TOOK PICTURES. SABER PROJECT. | |
| 03/15/2002 | FOLLOW UP CODE VIOLATION | Correction Required | MET AT SITE AND REVIEWED ELECTRICAL GROUNDING SYSTEMS THAT WERE INSTALLED. BOTH SITES WERE BONDED AT 2-RODS, GAS AND WATER LINES. MET OWNER TO REVIEW SMOKE DETECTORS AND WERE INSTALLED AT WRONG LOCATION AND WOULD BE MOVED BY END OF DAY. OWNER WAS GOING TO REMOVE PORCH AND HAS ELECTRICIAN WORKING ON OTHER ISSUES THAT NEED TO BE ADDRESS AND HAS BEEN IN CONTACT WITH HECTOR LOPEZ. UNIT THAT WAS ADDED WAS VACANT BUT BEING WORKED ON. | |
| 03/13/2002 | FOLLOW UP CODE VIOLATION | Correction Required | VIOLATION SUMMARY: WEST UNIT (5-7) COMPLEX VIOLATIONS: 1) UHC 301 & 1001.5: WORK W/O PERMITS & HAZ ELECTRICAL: THE MAIN SERVICE HAS DETERIORATED AND BEEN MODIFIED TO THE POINT OF NECESSITATING REPLACEMENT AND UPGRADING. CIRCUITS ARE INADEQUATE FOR LOAD, UNIT-6 CIRCUIT COMPLETLY LACKS FUSE PROTECTION, BONDING AND GROUNDING DOES NOT EXIST. CORRECTIONS REQUIRED: LICENSED ELECTRICAL CONTRACTOR WILL BE REQUIRED TO ADDRESS THE MAIN SERVICE. IF UNIT-5 IS TO REMAIN, FULL PLANS AND PERMITS WILL BE REQURED AND WILL FALL UNDER COMMERCIAL REQUIREMENTS. NEW SERVICE UPGRADE WILL BE REQUIRED. 2) UHC 301 & 1001.6: WORK W/O PERMITS & HAZ PLUMBING. GAS LINES, WATER LINES AND HOT WATER HEATERS HAVE BEEN REPLACED W/O PERMITS. GAS AND WATER LINES HAVE NOT BEEN INSTALLED TO CODE IN THAT THEY ARE NOT ANCHORED OR BURIED PROPERLY. THE HOT WATER TANK IS IN SEVERE DISREPAIR EVIDENCED BY THE SOOT BUILD UP AT THE GAS PILOT. THE INSTALLATION DOES NOT MEET CODE EVIDENCED BY THE VALVE, FLEX LINE AND STAND. CORRECTION REQUIRED: SECURE PERMITS FOR GAS LINES, WATER LINES AND HOT WATER TANK. CORRECTION REQUIRED: SECURE PERMIT FOR GAS AND WATER LINES.. 3) UHC 301 & 1001.5: WORK W/O PERMITS & HAZ ELECTRICAL. UNIT-6 APPEARS TO BE AN ENCLOSED CARPORT WITH ELECTRICAL AND PLUMBING ADDED. THE ELECTRICAL HAS BEEN INSTALLED IN A HAZARDOUS MANNER WITH EXPOSED WIRES, AND NO FUSE PROTECTION. CORRECTION REQUIRED: SUBMIT PLANS, SECURE PERMITS OR REMOVE UNIT. UNIT-5: 1) UHC 901: SMOKE DETECTORS: THE UNIT LACKS SMOKE DETECTORS. CORRECTION REQUIRED: INSTALL A SMOKE DETECTOR IN THE HALL AREA. 2) UHC 1001.3(6): STRUCTURAL: THE BEDROOM CIELING IS IN DISREPAIR. CORRECTION REQUIRED: REPAIR CIELING. 3) UHC 1001.8(2): WEATHER PROTECTION: THE UNIT LACKS WEATHER PROPER WEATHER PROTECTION EVIDENCED BY THE FRONT DOOR AND BROKEN WINDOWS IN THE BATHROOM AND FRONT DOOR. CORRECTION REQUIRED: SEAL THE FRONT DOOR AND REPAIR THE BROKEN WINDOWS. 4) UHC 1001.2(13): SANITATION: THE SHOWER STALL IS IN DISREPAIR. CORRECTION REQUIRED: REPAIR SHOWER STALL. UNIT-6: 1) UHC 901: SMOKE DETECTORS: THE UNIT LACKS SMOKE DETECTORS. CORRECTION REQUIRED: INSTALL ONE SMOKE DETECTOR IN THE HALL AREA. 2) UHC 701.3: HEAT: THE UNIT LACKS PROPER HEATING. CORRECTIONS REQUIRED: INSTALL PROPER HEATING. 3) UHC 1001.5: HAZARDOUS ELECTRICAL: THE ILLEGALLY INSTALLED ELECTRICAL HAS BENN INSTALLED IN A HAZARDOUS MANNER. THE CIRCUIT ON THE NORTH WALL HAS EXPOSED ROMEX AND TWO ELECTRICAL BOXES INSTALLED IN A HAZARDOUS MANNER. THE UNIT CONTAINS TWO FUSE SUB-PANELS THAT SERVICE UNITS 5 & 7. THE SUB-PANELS HAVE BEEN MOVED DUE TO THE ILLEGAL WORK OF UNIT-5. CORRECTION REQUIRED: SUBMIT PROPER PLANS AND SECURE PERMITS FOR UNIT. INSTALL ALL ELECTRICAL TO CODE. UNIT-7: 1) UHC 901: SMOKE DETECTORS: THE UNIT LACKS SMOKE DETECTORS. CORRECTION REQUIRED: INSTALL A SMOKE DETECTOR IN THE HALL AREA. 2) UHC 1001.3(6): STRUCTURAL: THE CIELING IN THE KITCHEN IS IN DISREPAIR. CORRECTION REQUIRED: REPAIR CIELING. 3) UHC 1001.5: HAZARDOUS ELECTRICAL: THE WASHING MACHINE WAS FOUND POWERED BY AN EXTENSION CORD. CORRECTION REQUIRED: REMOVE THE EXTENSION CORD. 4) UHC 1001.6: THE SANITARY SYSTEM HAS BEEN MODIFIED IN ORDER TO ACCOMODATE THE WASHING MACHINE. CORRECTION REQUIRED: SECURE PLUMBING PERMIT. 5) UHC 1001.8(2,3): WEATHER PROTECTION: THE UNIT LACKS PROPER WEATHER PROTECTION IN THAT THE FRONT & REAR DOORS DO NOT HAVE PROPER SEALS AND THE BATHROOM WINDOW WAS FOUND BROKEN. CORRECTION REQUIRED: PROPERLY SEAL THE FRONT AND REAR DOOR. REPLACE BROKEN WINDOW. 6) UHC 1001.9: FIRE HAZARD: THE FIRE RATING DOES NOT MEET CODE BETWEEN UNITS 6 & 7 DUE TO THE CONVERSION OF THE DUPLEX. WINDOWS AND DOORS HAVE BEEN INCORRECTLY FILLED IN. CORRECTION REQUIRED: SUBMIT PROPER PLANS AND SECURE PERMITS FOR UNIT 6. |