Permit: T02PL02357

Parcel: 122162280

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/28/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*PRESSURE TEST ON COMPLETE SYSTEM OK APPROVED REVISED PLAN ON JOB. PLUMBER TO PROVIDE PERMITS FOR NEW WATER HEATERS & CALL FOR INSP. CALL GAS CO 889-1888. CARD AT METER SET.
01/09/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*
PLEASE PROVIDE PROPER ENCLOSER FOR WATER HEATER FOR PROPER PROTECTION. VENT FOR WATER HEATER'S NOT SUSPENDED PROPERLY. WITH APPROVED LISTED CAP PLEASE HAVE PLUMBER LOOK AT SEC 608.5 RELIEF LINES # SHELL EXTEND OUTSIDE BLDG 6".
UNABLE TO COMPLETE INSP WITH OUT THE APPROVED PLAN W/TOTAL LENGTH & TOTAL BTU'S.
PLEASE HAVE THIS INFO BY NEXT INSP.
"NO SHOW BY CONTRACTORS."
01/02/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*1.) PLEASE PROVIDE APPROVED PLAN WITH TOTAL LENGTH & TOTAL BTU'S.
2.) PLEASE PROVIDE THIS INFO AT TIME OF NEXT INSP.
3.) CODE VIOLATIONS ON WATER HEATERS VENT AND RELIEF LINE
4.) NOBODY ON JOB DOOR LOCKED NO ACCESS.
5.) PLEASE PROVIDE ACCESS TO ROOF AT TIME OF NEXT INSP.