Permit: T02PL02355

Parcel: 130101370


Addresses:

3149 E 26TH ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESS TEST FNL

Date Description Inspector Results Comments
01/10/2003 PLUMBING - GAS PRESS TEST FNL Approved 1.) GAS PRESSURE TEST IS OK
2.) GAS SHUT OFF VALVES OK
3.) WATER HTR FLU VENTS, P & T VALVES & DRAIN IS OK
4.) FURANCE FLU VENT IS OK
5.) NOTE: OWNER WILL INSTALL A WATER HTR. ENCLOSURE AND CALL FOR FINAL INSPECTION.
01/09/2003 PLUMBING - GAS PRESS TEST FNL Denied IVRS - Inspection 0999*
1.) MUST PROVIDE TAPE PRIMER ON ALL JOINTS UNDERGROUND THEN APPLY 10MIL TAPE AROUND JOINT AND WRENCH MARKS.
2.) MUST REMOVE 3/4" GAS LINE UNDER SLAB TO RANGE AND REMOVE TEE TO GAS RANGE.
3.) MUST CUT OFF THREADED END OF P & T DRAIN FOR WATER HTR ON EAST END.
4.) MUST CONNECT FLU VENT FOR WATER HTR WEST SIDE.
5.) RE TEST SYSTEM.