Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESS TEST FNL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/10/2003 | PLUMBING - GAS PRESS TEST FNL | Approved | 1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES OK 3.) WATER HTR FLU VENTS, P & T VALVES & DRAIN IS OK 4.) FURANCE FLU VENT IS OK 5.) NOTE: OWNER WILL INSTALL A WATER HTR. ENCLOSURE AND CALL FOR FINAL INSPECTION. |
|
| 01/09/2003 | PLUMBING - GAS PRESS TEST FNL | Denied | IVRS - Inspection 0999* 1.) MUST PROVIDE TAPE PRIMER ON ALL JOINTS UNDERGROUND THEN APPLY 10MIL TAPE AROUND JOINT AND WRENCH MARKS. 2.) MUST REMOVE 3/4" GAS LINE UNDER SLAB TO RANGE AND REMOVE TEE TO GAS RANGE. 3.) MUST CUT OFF THREADED END OF P & T DRAIN FOR WATER HTR ON EAST END. 4.) MUST CONNECT FLU VENT FOR WATER HTR WEST SIDE. 5.) RE TEST SYSTEM. |