Permit: T02PL02143

Parcel: 117141000


Addresses:

19 E 15TH ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T02PL02143

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/04/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) CORRECTION MADE OK
2.) OK FOR GAS
3.) UCC LEFT AT METER
SW GAS 889-1888.
11/27/2002 PLUMBING - FINAL Denied 1.) GAS PIPING MAY NOT RUN ON THE GROUND. UNPROTECTED GAS PIPING MUST BE KEPT AT LEAST 6" AFG.
2.) MINIMUM PRESSURE TEST FOR GAS IS 10#.
3.) NO T&P RELIEF VALVE OR DRIAN ON WATER HEATER.