Permit: T02PL02027

Parcel: 138140390


Addresses:

501 W CALLE GARCIA

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/12/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) PETITION OF APPEAL STATES THAT THERE IS NO ACCESS TO THE OUTSIDE FOR THE T & P RELIEF DRAIN. THE LAUNDRY ROOM WALL CONNECTS. THE INTERIOR HALLWAY CLOSET TO THE EXTERIOR WALL. PLUMBING SUPERVISOR DIRECTED ME TO APPROVE THE PETITION OF APPEAL, SIGNED BY DAVE MANN BECAUSE AN EXPOSED DRAIN RUNNING DOWN THE LAUNDRY ROOM WALL WOULD BE UNSIGHTLY. HOME OWNER HAS BEEN INFORMED THAT FAILURE OF THE T & P VALVE COULD CAUSE FLOODING OF HIS HOME.
2.) UCC LEFT AT METER SW GAS 889-1888.
11/07/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) PERMIT FOR WATER HEATER T02PL00886 HAS EXPIRED WITHOUT A FINAL INSPECTION.
2.) DUMPING THE T&P DRAIN INTO THE PAN, AND ADDING A RELIEF VALVE IS NOT AN OPTION WHEN THE DRAIN CAN BE RUN TO THE OUTSIDE BY GRAVITY. (AS IT IS HERE) 3.) OK TO BACKFILL TRENCH.