Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02PL02022

Parcel: 121012330


Addresses:

1901 N CALLE SERENA

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/18/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*
11/14/2002 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*NOT READY FOR INSPECTION AS PER SKIP @ CUMMINGS PLBG.
11/13/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999* 1) PROVIDE VARIANCE FROM CITY TO ALLOW RETROFIT ON WATER HEATER T& P DRAIN.20 FURNACE VENT DOWS NOT HAVE ADEQUATE CLEARANCE FROM PLYWOOD. PROVIDE 6" FOR SINGLE WALL PIPE OR 1" FOR DOUBLE WALL PIPE. GAS PRESSURE TEST IS OK.
11/12/2002 PLUMBING - FINAL Not ready for Inspection NOT READY FOR INSPECTION.