Permit: T02PL02021

Parcel: 137031420


Addresses:

5249 S 6TH AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T02PL02021

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/18/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) CORRECTION MADE OK
2.) OK FOR GAS
3.) UCC LEFT AT METER SET SW GAS 889-1888.
11/14/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) GAS PIPING REQUIRES A MINIMUM OF 12" OF COVER. 2.) SEE NOTE #3 ABOVE 3.) SEE NOTE #4 ABOVE. 4.) NO TEP RELIEF DRAIN ON WATER HEATER. 5.) NO COLD WATER INLET SHUT OFF VALVE ON WATER HEATER. 6.) WATER HEATER MAY NOT BE PROPPED UP BLOCKS.
7.) ALL VALVES TO BE INSTALLED AND MUST BE AGA OR CSA APPROVED.
8.) CAP OFF ABANDONED GAS PIPING.
11/12/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*
1.) UNABLE TO LOCATE PERMIT.
2.) GAS PIPING SHALL NOT BE BENT OR STRAINED. CHANGES OF DIRECTION SHALL BE MADE WITH APPROVED.
3.) WHERE UNIONS ARE NECESSARY A RIGHT LEFT NIPPLE AND COUPLING SHALL BE USED.
4.) CAP OFF ALL ABANDONED GAS PIPING.
5.) SECURE PERMIT FOR NEW WATER HEATER. (OWNER SAYS W/H IS 5YRS OLD.NO RECORDS FROM THAT TIME. OK STEVE LONG. BUT WATER HEATER MUST MEET CODE.