Permit: T02PL01980


Addresses:

3300 S MANN AV #U


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T02PL01980

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/04/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) CORRECTION MADE OK 2.) OK FOR GAS 3.) UCC LEFT AT METER 4.) HOME OWNER ADVISED THAT T & P DRAIN COULD CAUSE INTERNAL FLOODING WILL CORRECT AT TIME OF REPLACING THE HEATER. 5.) UCC LEFT AT METER SW GAS 889-1888.
10/31/2002 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*1.) NEW PIPE & TEST OK 2.) REPLACE P & T VALVE IN WATER HEATER. 3.) REMOVE APPLIANCE CONNECTOR FROM FURANCE JACKET & REPLACE WITH STEEL PIPE. 4.) WRAP ALL PIPE JOINTS UNDERGROUND.