Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2002 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*CORRECTION MADE OK. OK FOR GAS. UCC LEFT AT METER. |
|
| 11/13/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) REQUIRED MINIMUM 10# AIR TEST TEST DOWN AT THIS TIME. | |
| 11/05/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) WHERE UNIONS ARE NECESSARY A RIGHT LEFT NIPPLE AND COUPLING SHALL BE USED. | |
| 11/04/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) UNDERGROUND GAS PIPING REQUIRES A MINIMUM OF TWELVE INCHES OF COVER. 2.) VENT CAP ON FLUE NOT APPROVED. 3.) WATER HEATER ENCLOSURE NOT SECURED TO WALL 4.) T&P RELIEF DRAIN LEAKING REPLACE VALVE. | |
| 10/31/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0000*1.) GAS PIPE COVERED WITHOUT INSPECTION ON PER MISSION. 2.) APPLIANCE CONNECTOR CANNOT PASS THROUGH JACKET OF WH ENCLOSURE. |