Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02PL01932


Addresses:

2926 W GORET RD


Inspection Status: Partial Approval

Inspection History: PLUMBING - SEWER HCS CONNECT

Permit Number - T02PL01932

Inspection Description - PLUMBING - SEWER HCS CONNECT

Inspection Status - Partial Approval

Date Description Inspector Results Comments
02/04/2003 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000*
1.) SEWER REPAIR MADE OK
2.) SEWER CONNECTION FOR LOT #16 OK OK TO MAKE FINAL CONNECTION TO MAIN.
3.) FIRE LINE DUG THROUGH SEWER FOR COMMON BUILDING REPAIR MADE OK OK TO COVER.
01/30/2003 PLUMBING - SEWER HCS CONNECT Denied IVRS - Inspection 0999*1.) INTERMINGLING OF MAT'L TYPES NOT ALLOWED.
2.) HIGH TRAFFIC AREA COUPLINGS TO BE SHIELDED.
3.) SDR 35 SEWER NEXT TO WATER LINE REQUIRES 12" X 12" SEPARATION.
4.) LEAK IN WATER LINE HAS SATURATED TEST AREA.
5.) FITTINGS COVER UNCOVER FOR INSPECTION.
11/25/2002 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection 0000*
10/30/2002 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000*REPAIR ON HCS FOR UNIT #16, TEST FROM CO #15 TO CO #17 OK LOT. #18, 16, 27, 28 HCS TEST OK LOT.
10/25/2002 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000*#1. HCS FOR BLDG 3035
10/24/2002 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection 0000*