Inspection Status: Partial Approval
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T02PL01932
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Partial Approval
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/04/2003 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection 0000* 1.) SEWER REPAIR MADE OK 2.) SEWER CONNECTION FOR LOT #16 OK OK TO MAKE FINAL CONNECTION TO MAIN. 3.) FIRE LINE DUG THROUGH SEWER FOR COMMON BUILDING REPAIR MADE OK OK TO COVER. |
|
| 01/30/2003 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection 0999*1.) INTERMINGLING OF MAT'L TYPES NOT ALLOWED. 2.) HIGH TRAFFIC AREA COUPLINGS TO BE SHIELDED. 3.) SDR 35 SEWER NEXT TO WATER LINE REQUIRES 12" X 12" SEPARATION. 4.) LEAK IN WATER LINE HAS SATURATED TEST AREA. 5.) FITTINGS COVER UNCOVER FOR INSPECTION. |
|
| 11/25/2002 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection 0000* | |
| 10/30/2002 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection 0000*REPAIR ON HCS FOR UNIT #16, TEST FROM CO #15 TO CO #17 OK LOT. #18, 16, 27, 28 HCS TEST OK LOT. | |
| 10/25/2002 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection 0000*#1. HCS FOR BLDG 3035 | |