Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T02PL01926
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/20/2003 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*13 PSI TEST. REMOVE UNION FROM GAS LINE ON ROOF USE REVERSE THREAD COUPLING & NIPPLE. RETEST SYSTEM. |
|
02/19/2003 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection 0000* | |
02/12/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999* 1.) GAS FLEX TO FURNACE CANNOT EXCEED 3' IN LENGTH. 2.) REPLACE GAS SHUT OFF VALVES TO FURNACE USE AGA APPROVED VALVES. 3.) PROVIDE A ROOF JACK WHERE GAS PIPE PENETRATES THE ROOF. 4.) BLOCK & CLAMP GAS PIPE ON ROOF. 5.) PROVIDE MIN. 10 LB. TEST ON GAS SYSTEM. RECALL FOR INSPECTION. |