Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESS TEST FNL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/22/2002 |
PLUMBING - GAS PRESS TEST FNL |
|
Approved |
IVRS - Inspection 0000* |
| 10/20/2002 |
PLUMBING - GAS PRESS TEST FNL |
|
Denied |
IVRS - Inspection 0999*1.) A FLEX CONNECTOR MAY NOT PASS THROUGH A WALL OR PARTITION HARD PIPE TO INSIDE ENCLOSURE 2.) FLEX CONNECTOR EXCEEDS ALLOWABLE LENHTH. 3.) A DRYER VENT IS NOT APPROVED AS A VENT CONNECTOR. |
| 10/14/2002 |
PLUMBING - GAS PRESS TEST FNL |
|
Denied |
IVRS - Inspection 0999*1.) WATER HTR REQUIRES A ENCLOSURE TO PROTECT IT FROM THE ELEMENTS. 2.) MUST REPLACE P & T VALVE AND CUT OFF THREADS @ END OF P & T DRIAN. 3.) P & T DRAIN MUST TERMINATE NO HIGHER THAN 24" ABOVE GRADE AND NOT LESS THAN 6" ABOVE GRADE. 4.) GAS SHUT OFF VALVE FOR RANGE IS OK. |
| 10/14/2002 |
PLUMBING - GAS PRESS TEST FNL |
|
Not ready for Inspection |
IVRS - Inspection 0000*NOT READY FOR INSPECTION. |