Permit: T02PL01830

Parcel: 129133110


Addresses:

2402 S PARK AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESS TEST FNL

Date Description Inspector Results Comments
10/22/2002 PLUMBING - GAS PRESS TEST FNL Approved IVRS - Inspection 0000*
10/20/2002 PLUMBING - GAS PRESS TEST FNL Denied IVRS - Inspection 0999*1.) A FLEX CONNECTOR MAY NOT PASS THROUGH A WALL OR PARTITION HARD PIPE TO INSIDE ENCLOSURE 2.) FLEX CONNECTOR EXCEEDS ALLOWABLE LENHTH. 3.) A DRYER VENT IS NOT APPROVED AS A VENT CONNECTOR.
10/14/2002 PLUMBING - GAS PRESS TEST FNL Denied IVRS - Inspection 0999*1.) WATER HTR REQUIRES A ENCLOSURE TO PROTECT IT FROM THE ELEMENTS. 2.) MUST REPLACE P & T VALVE AND CUT OFF THREADS @ END OF P & T DRIAN. 3.) P & T DRAIN MUST TERMINATE NO HIGHER THAN 24" ABOVE GRADE AND NOT LESS THAN 6" ABOVE GRADE. 4.) GAS SHUT OFF VALVE FOR RANGE IS OK.
10/14/2002 PLUMBING - GAS PRESS TEST FNL Not ready for Inspection IVRS - Inspection 0000*NOT READY FOR INSPECTION.