Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/27/2002 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*1.) ALL CORRECTION MADE OK 2.) OK FOR GAS 3.) UCC LEFT AT METER. 4.) SW GAS 889-1888. |
| 09/24/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) NO TEST ON GAS PIPING REQUIRES MINIMUM #10 TEST. 2.) CAP OFF ABANDONED GAS PIPING. 3.) CONNECT WATER HEATER GAS PIPING COMPLETE. 4.) CODE REQUIRES THAT UNDERGROUND GAS PIPING HAVE AT LEAST 12" COVER. |
| 09/16/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0000*TEST COMPLETE SYSTEM. 2.) REPLACE P & T VALVE IN WATER HEATER 3.) REMOVE FLEXABLE APPLIANCE CONNECTOR FROM PASSING THROUGH DRYWALL & FURANCE JACKET & REPLACE WITH STEEL PIPE. 4.) FIRE PLACE REQUIRES VALVE OUTSIDE FINE BOX IN ROOM WITH FIRE PLACE. |