Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T02PL01657
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/27/2002 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*1.) ALL CORRECTION MADE OK 2.) OK FOR GAS 3.) UCC LEFT AT METER. 4.) SW GAS 889-1888. | |
| 09/24/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) NO TEST ON GAS PIPING REQUIRES MINIMUM #10 TEST. 2.) CAP OFF ABANDONED GAS PIPING. 3.) CONNECT WATER HEATER GAS PIPING COMPLETE. 4.) CODE REQUIRES THAT UNDERGROUND GAS PIPING HAVE AT LEAST 12" COVER. | |
| 09/16/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0000*TEST COMPLETE SYSTEM. 2.) REPLACE P & T VALVE IN WATER HEATER 3.) REMOVE FLEXABLE APPLIANCE CONNECTOR FROM PASSING THROUGH DRYWALL & FURANCE JACKET & REPLACE WITH STEEL PIPE. 4.) FIRE PLACE REQUIRES VALVE OUTSIDE FINE BOX IN ROOM WITH FIRE PLACE. |