Permit: T02PL01566

Parcel: 133224180


Addresses:

7002 E KINGSTON DR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
08/27/2002 PLUMBING - GAS PRESSURE TEST Approved 1.) PE GAS PIPING MUST HAVE A MIN. OF 18" OF COVER SEE SECTION 315.1 94 UPC INSTALLATION STANDARDS. 2.) CAN NOT USE THREAD PRTECTOR COUPLING IN GAS LINE MUST USE APPROVED COUPLING. 3.) MUST REMOVE 3/4" X 1/2" X 3/4 TEE WITH PLUG. 4.) MUST PROVIDE APPROVED GAS SHUT OFF VALVES FOR FURANCE & WATER HTR WITH AGA OR CSA VAVLES. 5.) MUST LOCATE GAS SHUT OFF VALVE BEFORE THE UNION @ HOUSE CONNECTION. 6.) RE TEST SYSTEM 10LBS MIN. @ TIEM OF INSPECTION. 7.) MUST REMOVE UNION @ METER.