Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T02PL01419
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/04/2002 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*1.) ALL NECESSARY CORRECTION MADE OK 2.) PLUMBING FINAL OK 3.) OK FOR GAS 4.) OK TO COVER. 5.) UCC LEFT AT METER 6.) SW GAS. | |
08/30/2002 | PLUMBING - FINAL | Not ready for Inspection | NOT READY FOR INSPECTION. | |
08/29/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*WAS PERMTI SECURED FOR THE NEW WATER HEATER ONLY ONE LOOKS LIKE IT WAS PRE-EXISTING CONDITION 2.) PROVIDE LISTING FOR VENT SEE NOTE #3 ABOVE. 3.) YOU'RE STREATCHING THE 12" MINIMUM COVER ON THE UNDERGROUND PIPING. 4.) PIPING SHALL NOT BE BENT OR STAINED, CHANGES OF DIRECTION SHALL BE MADE WITH APPROVED FITTINGS 5.) 1" REQUIRED GAS PIPING MUST CONTINUE UNDIMINSHED TO FIRST BRANCH. REDUCING TO 3/4" MIDWAY, DOES NOTHING FOR ASSURING ADEQUETE VOLUME 6.) PLEASE HAVE A JOURNEY MAN PLUMBER CHECK ALL WORK. | |
08/16/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0000*1.) WATER HEATER REQUIRES WORKING P & T VALUE 2.) P & T DISCHANGE MUST BE INSTALLED TO DRAIN WATER DOWN & OUTSIDE NOT THROUGH ROOF 3.) WATER HEATER REQUIRES APPROVED TYPE VENT. 4.) GAS PIPE UNDERSIZED. | |
08/06/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) PLUMBER INSTALLED TWO NEW GAS LINES TO 2 APTS. 2.) SCOTCHCOAT SHALL HAVE A MINIMUM OF 12 INCHES COVER. 3.) WHERE PIPING MEETS THE CONNECTION SHALL BE MADE WITH A RIGHT-LEFT NIPPLE AND COUPLING. 4.) ALL VALVES TO BE AGA OR CSA APPROVED INSTALL ALL VALVES. 5.) T & P RELIEF DRAIN INOPENABLE. WHEN REPLACING DO NOT RUN THROUGH ROOF MUST BE GRAVITY DRAIN TO EXTERIOR OF BLDG. 6.) INADEQUETE COMBUSTION RELIEF IN WATER HEATER CLOSETS 7.) HAVE PLUMBER CHECK ALL WORK THIS MAY NOT BE A COMPLETE LIST OF CODE VIOLATIONS. |