Inspection History: PLUMBING - FINAL

Permit Number - T02PL01418

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/04/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*ALL NECESSARY CORRECTIONS MADE OK 2.) PLUMBING FINAL OK 3.) OK TO COVER OK FOR GAS UCC LEFT AT METER.
08/30/2002 PLUMBING - FINAL Not ready for Inspection
08/29/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*WAS PERMIT SECURED FOR THE NEW WATER HEATER? ONLY ONE LOOKS LIKE IT WAS PRE-EXISTING CONDITION 2.) PROVIDE LISTING FOR VENT VENT CONNECTOR TO BE TAPED AND SCREWED PER CODE. 3.) MINIMUM 12" COVER IS QUESTIONABLE. 4.) PIPING SHALL NOT BE BENT OR STRAINED. 5.) 1" REQUIRED GAS SIZE IS TO RUN UNDIMINSHED IN SIZE TO FIRST BRANCH, OR YOURE DEFEATED UPSIZING THE LINE 6.) PLEASE HAVE A JOUREYMAN PLUMBERS CHECK ALL WORK.
08/16/2002 PLUMBING - FINAL Denied IVRS - Inspection 0000*1.) P & T DRAIN TRAPOUT. MUST BE RAN DOWN & OUT SIDE. 2.) P & T VALUE BE MUST WORK 3.) GAS PIPE UNDER SIZE.
08/06/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) PLUMBER INSTALLED TWO NEW GAS LINES TO 2 APTS. 2.) SCOTCHCOAT SHALL HAVE A MINIMUM OF 12INCHES COVER. 3. WHERE PIPING MEETS THE CONNECTION SHALL BE MADE WITH A RIGHT LEFT NIPPLE AND COUPLING. 4.) ALL VALVES TO BE AGA OR CSA APPROVED INSTALLED ALL VALVES. 5.) T&P RELIEF DRAIN INOPENABLE WHEN REPLACING DO NOT RUN THROUGH ROOF MUST BE GRAVITY DRAIN TO EXTERIOR OF BLDG. 6.) INADEQUETE COMBUSTION RELIEF IN WATER HEATER CLOSETS. 7.) HAVE PLUMBER CHECK ALL WORK THIS MAY NOT BE A COMPLETE LIST OF CODE VIOLATION.