Permit: T02PL01396

Parcel: 122181170


Addresses:

1536 N DODGE BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/13/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*GAS PRESSURE TEST IS OK.
08/12/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) SEE NOTE #4 AS REQUESTED 2.) CHECK SYSTEM FOR POSSIBLE LEAK.
08/06/2002 PLUMBING - FINAL Denied 1.) WATER HTR FLU VENT DOES NOT HAVE TERMINATION OF VENT MIN 3'-0" ABOVE COOLER SEE SECTION 517.6 94 UPC. 2.) P & T VALVE IS STUCK SHUT. 3.) MUST SCREW DOWN FLU VENTS FOR WATER HTR FURNACE WITH 3 SHEET METAL SCREWS PER JOINT. 4.) GAS PRESSURE TEST WAS BELOW 10LBS CHECK SYSTEM.