Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T02PL01389
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/06/2002 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection 0000* | |
| 08/05/2002 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection 0999* | |
| 08/01/2002 | PLUMBING - GAS PRESSURE TEST | Denied | 1.) WATER HTR P & T VALVE IS STUCK CLOSED 2.) WATER HTR FLU VENT DBL WALL REQUIRES 1" CLEARANCE AROUND COMBUSTIONABLE MATERIAL 3.) MUST CALCULATE BTU & CFH DEMAND FOR GAS LINE SIZEING. 4.) GAS RANGE HAS 3/4" OUTLET THEN SUPPLY MUST BE 3/4" 5.) WATER HTR ENCLOSURE REQUIRE 2 10 X 10 GRILLS FOR FRESH AIR COMBUSTION RELIEFE 6.) MUST STRAP GAS LINE EVERY 6'-0". 7.) MUST SEAL PENETRATION THRU WALLS. |