Permit: T02PL01372

Parcel: 12112399F


Addresses:

1646 N BEVERLY AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/26/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*GAS PRESSURE TEST IS OK. 2.) GAS SHUT OFF VALVES OK
3.) WATER HTR FLU VENT, P & T VALVE & DRAIN IS OK
4.) FURNANCE FLU VENT OK.
11/22/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*CAN NOT HAVE FLEX LINE ON P & T DRAIN.
08/27/2002 PLUMBING - FINAL Denied 1.) MUST SCREW DOWN FLU VENTS FOR WATER HTR. & FURANCE WITH 3 SHEET METAL SCREWS PER JOINT AND @ APPLIANCE COLLAR. 2.) MUST RUN P & T DRAIN TO DAYLIGHT AND NO THREADS @ END OF DRAIN ALLOWED. 3.) MUST PROVIDE AGA OR CSA GAS SHUT OFF VALVE & FLEX CONNECTOR FOR RANGE.