Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/26/2002 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000* 1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES OK 3.) WATER HTR FLU VENT, P & T VALVE & DRAIN IS OK 4.) NOTE: OWNER OF DWELLING HAS STATED THAT THE EXISTING FURNACE IS NOT WORKING @ THIS TIME AND THIS UNIT WILL BE REPLACED @ A LATER TIME. THE GAS SUPPLY TO THIS VENT HAS BEEN PERMANENTLY CAPPED AS WELL AS SUPPLY FO RRANGE. OWNER HAS BEEN ADVISED ABOUT MECH. PERMIT. |
| 07/25/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999* 1.) WATER HTR. 1.) SINGLE WALL FLU VENT FOR WATER HTR MUST HAVE 6" CLEARANCE FROM COMBUSTIONABLE MATERIAL. 2.) DOUBLE WALL FLU VENT MUST HAVE 1" CLEARANCE AROUND COMBUSTIONABLE MATERIAL. 3.) FURNACE FLU VENT SEEMS TO BE OF NOW METALIC MATERIAL. REPLACE WITH APPROVED FLU VENT MATERIAL AND PROVIDE (3) SHEET METAL SCREWS PER JOINTS. 4.) FURNACE MUST HAVE A APPROVED GAS SHUT OFF VALVES. 5.) MUST VERIFY APPROVED GAS SHUT OFF VALVE FOR RANGE & WATER HTR. 6.) B-VENT TERMINATION MUST BE MIN 12" ABOVE ROOF. |