Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 07/31/2002 |
PLUMBING - INTERMEDIATE |
|
Approved |
|
| 07/25/2002 |
PLUMBING - INTERMEDIATE |
|
Cancelled |
IVRS - Ri canceled |
| 07/23/2002 |
PLUMBING - INTERMEDIATE |
|
Denied |
1.) FLU VENT FOR WATER HTR MUST HAVE (3) SHEET METAL SCREWS PER JOINT ON VENT CONNECTOR AND ALL JOINTS 2.) MUST PROVIDE A APPROVED ROOF FLASHING WHEN PENERATING ROOF WITH 3/4" GAS LINE 3.) FLU VENT TERMINATION MUST BE MIN 3'-0" ABOVE COOLER SEE SECTION 517.6 94 UPC. 4.) MUST HAVE A LICENSE PLBG. CONTRACTOR TO DO ANY WORK ON GAS SYSTEM ON RENTAL PROPERTY. 5.) AZ REGISTER FO CONTRACTOR RECORDS INDICATE THAT CONTRACTOR ABOVE HAS NO ACTIVE LICENSE ON FILE. |