Permit: T02PL01314

Parcel: 112042130


Addresses:

3142 N TUCSON BL

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
07/31/2002 PLUMBING - INTERMEDIATE Approved
07/25/2002 PLUMBING - INTERMEDIATE Cancelled IVRS - Ri canceled
07/23/2002 PLUMBING - INTERMEDIATE Denied 1.) FLU VENT FOR WATER HTR MUST HAVE (3) SHEET METAL SCREWS PER JOINT ON VENT CONNECTOR AND ALL JOINTS 2.) MUST PROVIDE A APPROVED ROOF FLASHING WHEN PENERATING ROOF WITH 3/4" GAS LINE 3.) FLU VENT TERMINATION MUST BE MIN 3'-0" ABOVE COOLER SEE SECTION 517.6 94 UPC. 4.) MUST HAVE A LICENSE PLBG. CONTRACTOR TO DO ANY WORK ON GAS SYSTEM ON RENTAL PROPERTY. 5.) AZ REGISTER FO CONTRACTOR RECORDS INDICATE THAT CONTRACTOR ABOVE HAS NO ACTIVE LICENSE ON FILE.