Permit: T02PL01294

Parcel: 110041930


Addresses:

4401 E CALADIUM PL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/12/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) CONVERSATION WITH PLBG. CONTRACTOR AND HE STATED THAT THERE WOULD BE NO CONCRETE PATCH ON TRENCH UNDER PORCH. REMOVABLE PAVERS HAVE BEEN INSTALLED.
07/19/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1) I APPEARS THAT THE 3/4" COPPER WATER SERVICE WILL BE UNDER CONCRETE THEN PAVERS. IF THIS IS THE CASE THEN THE COPPER FITTINGS UNERSLAB MUST E SILVER BRAZED. 2.) OK TO BACKFILL TRENCH UP TO THIS POINT ONLY.