Permit: T02PL01250

Parcel: 125072730


Addresses:

2021 E 6TH ST #02

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/02/2002 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000* 1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES IS OK 3.) WATER HTR FLU VENT P & T DRAIN, VALVE & DRAIN IS EXSISTING. 4.) WALL FURNACE FLU VENT OK.
07/25/2002 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) MUST EXPOSE GAS LINE UNDERGROUND @ RISER CONNECTIONS AND 2 PLACES ALONG GAS RUN 2.) MUST REMOVE UNION IN LINE AND REPLACE WITH RIGHT & LEFT HAND NIPPLE. 3.) MUST REPLACE GAS SHUT OFF VALVE @ WALL FURANCE WITH AGA OR CSA VALVE. 4.) MUST SCREW DOWN FLU VENT WITH (3) SHEET METAL SCREWS PER JOINT FOR WATER HTR. 5.) RETEST SYSTEM 10 LBS MIN.