Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/12/2002 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*1. CORRECTIONS MADE OK 2.) OK FOR GAS 3.) UCC LEFT AT METER LOCATION. |
| 07/09/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) GAS PIPING PASSING THROUGH THE ROOF SHALL HAVE APPROVED FLASHING. 2.) SECURE GAS DROP AT STOVE. 3.) OK TO BACKFILL TRENCH. |
| 06/17/2002 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) PROVIDE GAS ISOMETIC SHOWING TOTAL DEVELOPED LENGTH AND B.T.U. CONSUMPTION. 2.) ARIZONA LAW REQUIRES THIS WORK TO BE PEFORMED BY A LICENSED PLUMBING CONTRACTOR. 3.) GAS PIPE MAY NOT PASS UNDER THE BLDG. 4.) ALL VALVES TO BE AGA OR CSA APPROVED. 5.) NO AIR TEST AT THIS TIME 10# FOR FIFTEEN MINUTES BEFORE THE INSPECTOR ARRIVES 6.) ALL UNDERGROUND GAS PIPING TO BE A MINIMUM 12" BELOW GRADE. |