Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 07/08/2002 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
IVRS - Inspection 0000* |
| 07/02/2002 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999* |
| 06/20/2002 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999*1.) APT MISSING STOVE SHUT OFF VALVE. MUST BE AGA OR CSA APPROVED FLEX CONNECTOR MAY NOT PASS THRU PARTITION 2.) WHERE PIPING MEETS THE CONNECTION SHALL BE MADE WITH RIGHT - LEFT NIPPLE AND COUPLING 3.) WHERE PIPING PASSES THRU ROOF, AN APPROVED FLASHING SHALL BE USED. 4.) A WATER HEATER VENT MUST RISE 5' MINIMUM FROM COLLAR. |