Permit: T02PL00997

Parcel: 129130170


Addresses:

838 E SILVERLAKE RD

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
05/23/2002 PLUMBING - GAS PRESSURE TEST Approved
05/22/2002 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*1.) ALL PIPING 6" AFG AND BELOW TO BE SCOTHCOAT 2.) ALL FITTINGS AND MARRD PIPE BELOW GRADE TO BE PRIMED AND TAPED. 3.) DO NOT CHANGE PIPE SIZE BEFORE FIRST BRANCH. RUN 3/4" PIPE ALL THE WAY TO THE FIRST TEE. 4.) ROOF PENETRATIONS REQUIRE FLASHINGS. 5.) USE A SWING JOINT ON THE ROOF, AND SUPPORT THE PIPING 1 1/2" ABOVE ROOF. 6.) NO COMBUSTION RELIEF FOR WATER HEART, AND WATER HEATER ROOM OPENS INTO A BEDROOM. 7.) SUPPORT GAS DROPS.